12 

Connection plan 

The 1-Wire solar sensor is connected via Push In terminals. The connection terminal is intended for solid wires 
or finely stranded cables of 0.2 to 1.5qmm cross-
section.  
The pin assignment is printed on the printed 
circuit board.  
The correct polarity of the connection must be 
observed. 
The Multisensor is equipped with three cables  
(ground, 1-Wire Data and 5V).  
Parasitic mode is not supported. 
Note: Basics and tips for the 1-Wire bus system 
can be found on the ESERA website at 

https://www.esera.de/1-wire-grundlagen/ 

  

13 

Assembly 

If the sensor is used to control shades or roller shutters, the sensor should be oriented to the south. If room lighting 
is to be controlled, orientation to the north is preferable. Ensure that the sensor is not shaded by trees or chimneys. 

 

14 

Operating conditions 

The module may only be operated at the specified voltages and ambient conditions. The device can be 
operated in any position. The sensor is designed for continuous operation outdoors or in rooms with high 
humidity.  
If condensation forms inside the sensor, an acclimatization time of at least 2 hours must be waited for.  
Do not operate the module in an environment in which flammable gases, vapors or dusts are present or may be 
present. 

  

15 

Disposal note 

Do not dispose of the device within the household waste! 
According to the directive concerning old electrical and electronic appliances, 
electronic devices must be disposed of via the collecting points for old electronic 
appliances! 
 

16 

Safety instructions 

When using products that come into contact with electrical voltage, the valid VDE regulations must be observed, especially VDE 
0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860 

 

All final or wiring work must be carried out with the power turned off. 

 

Before opening the device, always unplug or make sure that the unit is disconnected from the mains. 

 

Components, modules or devices may only be put into service if they are mounted in a contact proof housing. During 
installation they must not have power applied. 

 

Tools may only be used on devices, components or assemblies when it is certain that the devices are disconnected 
from the power supply and electrical charges stored in the components inside the device have been discharged. 

 

Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults or 
breaks. 

 

If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty cable has 
been replaced. 

 

When using components or modules it is absolutely necessary to comply with the requirements set out in the 
accompanying description specifications for electrical quantities. 

 

If the available description is not clear to the non-commercial end-user what the applicable electrical characteristics for 
a part or assembly are, how to connect an external circuit, which external components or additional devices can be 
connected or which values these external components may have, a qualified electrician must be consulted. 

 

It must be examined generally before the commissioning of a device, whether this device or module is basically 
suitable for the application in which it is to be used. 

 

In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary. 

 

For operational and connection errors outside of our control, we assume no liability of any kind for any resulting 
damage. 

 

Kits should be returned without their housing when not functional with an exact error description and the accompanying 
instructions. Without an error description it is not possible to repair. For time-consuming assembly or disassembly of 
cases charges will be invoiced. 

 

During installation and handling of components which later have mains potential on their parts, the relevant VDE 
regulations must be observed. 

 

Devices that are to be operated at a voltage greater than 35 VDC / 12mA, may only be connected by a qualified 
electrician and put into operation. 

 

Commissioning may only be realized if the circuit is built into a contact proof housing. 

 

If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be installed 
upstream or a suitable power supply can be used.  

 

Summary of Contents for 11112

Page 1: ...ties cover the entire range of applications for recording solar radiation and day night detection and are therefore ideally suited for central light shutter and shade control The 1 Wire Solar Multisensor is designed for permanent outdoor operation The entire sensor is designed for a temperature range of 40 to 85 C To ensure maximum reliability the 1 Wire Solar Multisensor has an integrated monitor...

Page 2: ...tness Art No 11135 3 Technical data 1 Wire chip device 1 x DS2438 Multisensor Solar sensor Measuring range up to approx 1200 W m2 converted approx 1 000 70 000 lux PV measuring cell is a high quality monocrystalline glass PV cell Detection range 50 for half sensitivity Functions DS2438 XSens 0mV darkness resolution 10mV 10 Bit Brightness sensor Measuring range 10 approx 7000 Lux Peak sensitivity 5...

Page 3: ...in IP Symcon ESERA Station At our website we provide ESERA IP Symcon software modules for reading the 1 Wire Multisensor into IP Symcon via 1 Wire Controller 1 Wire Gateway No scripts are necessary Details can be found on the ESERA website under Compatible control systems central control systems IP Symcon integration https www esera de kompatible steuerungen zentralen ip symcon integration For the...

Page 4: ...Components modules or devices may only be put into service if they are mounted in a contact proof housing During installation they must not have power applied Tools may only be used on devices components or assemblies when it is certain that the devices are disconnected from the power supply and electrical charges stored in the components inside the device have been discharged Live cables or wires...

Page 5: ...lacement is faulty the buyer has the right to have the original purchase price refunded or a reduction of the purchase price ESERA Automation accepts liability neither for the constant and uninterrupted availability of the ESERA Automation or for technical or electronic errors in the online offer We develop our products further and we reserve the right to make changes and improvements to any of th...

Reviews: