If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be 
installed upstream or a suitable power supply can be used.  

 

After installing the required tests according to DGUV / regulation 3 (German statutory accident insurance,

 

https://en.wikipedia.org/wiki/German_Statutory_Accident_Insurance

must be carried out. 

 

13 

Warranty 

ESERA GmbH guarantees that the goods sold at the time of transfer of risk to be free from material and workmanship 
defects and have the contractually assured characteristics. The statutory warranty period of two years begins from date of 
invoice. The warranty does not extend to the normal operational wear and normal wear and tear. Customer claims for 
damages, for example, for non-performance, fault in contracting, breach of secondary contractual obligations, 
consequential damages, damages resulting from unauthorized usage and other legal grounds are excluded. Excepting to 
this, ESERA GmbH accepts liability for the absence of a guaranteed quality resulting from intent or gross negligence. 
Claims made under the Product Liability Act are not affected. 
If defects occur for which the ESERA GmbH is responsible, and in the case of replacement goods, the replacement is 
faulty, the buyer has the right to have the original purchase price refunded or a reduction of the purchase price. 
ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical 
or electronic errors in the online offer. 
We are constantly developing our products further and reserve the right to make changes and improvements to any of the 
products described in this documentation without prior notice. Should you require documents or information on older 
versions, please contact us by e-mail at 

[email protected]

 

 

14 

Trademarks 

All mentioned designations, logos, names and trademarks (including those which are not explicitly marked) are 
trademarks, registered trademarks or other copyright or trademarks or titles or legally protected designations of their 
respective owners and are hereby expressly recognized as such by us. The mention of these designations, logos, names 
and trademarks is made for identification purposes only and does not represent a claim of any kind on the part of ESERA 
GmbH on these designations, logos, names and trademarks. Moreover, from their appearance on ESERA GmbH 
webpages it cannot be concluded that designations, logos, names and trademarks are free of commercial property rights. 

ESERA and Auto-E-Connect are registered trademarks of ESERA GmbH. 

 

15 

Contact 

ESERA GmbH 
Adelindastrasse 20 
87600 Kaufbeuren 
GERMANY 
Tel.: +49 8341 999 80-0 
Fax: +49 8341 999 80-10 

www.esera.de

 

[email protected]

 

WEEE-Number: DE30249510

 

 

Summary of Contents for 1-Wire Controller 1

Page 1: ... the 1 Wire network Active termination 1 Wire Term 1 is highly recommended for increasing the maximum line length and improving the system stability of the 1 Wire network especially with long 1 Wire lines and with a setup in star or tree topology In a 1 Wire network up to 3 pieces of 1 Wire Term 1 modules can be connected The 1 Wire Term 1 is very compact and can be ideally installed in a flush mo...

Page 2: ...ESD EN 61000 4 3 HF EN 61000 4 4 Burst EN 61000 4 5 Surge EN 61000 6 1 interference immunity EN 61000 6 3 interference radiation RoHS 7 Integration in 1 Wire Network The 1 Wire Term 1 module is mounted at the end of a 1 Wire network cable If the 1 Wire network is star shaped i e with several 1 Wire cable sections a 1 Wire Term 1 module should be connected to each end No more than three 1 Wire Term...

Page 3: ... the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11355 V2 0 R1 0 Manual Page 3 of 5 8 Connection example Note Basics and tips for the 1 Wire bus system can be found in our eBook in the shop at https www esera de service support 1 wire grundlagen ...

Page 4: ...aste Electrical and Electronic Equipment 12 Safety instructions When using products that come into contact with electrical voltage the valid VDE regulations must be observed especially VDE 0100 VDE 0550 0551 VDE 0700 VDE 0711 and VDE 0860 All final or wiring work must be carried out with the power turned off Before opening the device always unplug or make sure that the unit is disconnected from th...

Page 5: ...affected If defects occur for which the ESERA GmbH is responsible and in the case of replacement goods the replacement is faulty the buyer has the right to have the original purchase price refunded or a reduction of the purchase price ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical or electronic errors in the online offer We a...

Reviews: