![ESD CAN-PC104/200 Hardware Installation And Technical Data Download Page 18](http://html1.mh-extra.com/html/esd/can-pc104-200/can-pc104-200_hardware-installation-and-technical-data_2426433018.webp)
Technical Data
4. Technical Data
4.1 General Technical Data
Ambient
temperature
0...50°C
Humidity
90 %, non-condensing
Power Supply
via PC/104-bus,
nominal voltage: 5 V ±5%,
current (20°C, all CAN controllers equipped):
I
TYP
= 250 mA
Connectors
X100 (64-pole PC/104 PCB connector) - PC/104 bus
X101 (40-pole PC/104 PCB connector) - PC/104 bus
X400 (DSUB9/male) - CAN interface 1 (ISO11898)
The following connectors are only equipped for programming and service:
X102 (8-pole male connector)
- ISP programming
Dimensions
95.9 mm x 90.2 mm
Weight
< 150 g
Table 3:
General technical data
4.2 PC/104 Bus
Host bus
PC/104
PC/104-data bus
8 bit
Interrupt
1 out of 12
Connectors
PC/104 PCB connectors, 40-pole and 64-pole
Table 4:
PC/104 bus data
Page 18 of 31
Hardware Manual • Doc. No.: C.2013.21 / Rev. 1.7
CAN-PC104/200