Connector Assignments
4.2.1 Connector Assignment
Device connector :
Phoenix Contact MC 1,5/5-GF-3,81
Line connector:
Phoenix Contact FK-MCP 1,5/5-STF-3,81, spring-cage connection
Phoenix Contact Order No.: 1851261 (included in delivery)
For conductor connection and conductor cross section see page 37.
Pin Position:
Pin Assignment:
(device connector view)
Labelling
Signal
Pin
G
CAN1_GND
1
L
CAN1_L
2
Sh
Shield
3
H
CAN1_H
4
•
-
5
Signal description:
CAN1_L, CAN1_H ... CAN1 signals
CAN1_GND ...
reference potential of the local CAN1 physical layer
Shield ...
pin for line shield connection (using hat rail mounting direct contact to the
mounting rail potential) connected to earth potential (FE)
- ...
not connected
Recommendation of an adapter cable from 5-pin line connector (here line connector
FK-MCP1,5/5-STF_3,81 with spring-cage-connection) to 9-pin DSUB:
The assignment of the
9-pin DSUB-connector is
designed according to
CiA DS-102.
The assignment of the
5-pin line connector
is designed according to
CiA DR-303 Part 1
Page 28 of 53