background image

iMiniPlus PDF Logger User Guide v2.0 

 

 

- 24 - 

time to time. Additionally some Help documentation may not be present due to the software version you are 
currently using. Consult this iMiniPlus PDF Logger User guide if you are not sure about any description.

 

      

 

     

 

 

You have the option of programming new start conditions. This may be help for instance when you are having to 
reset a large number of iMiniPlus loggers for a new application. Otherwise leave the Logger option at its default 
setting “Do not upload any new start conditions to the logger(s)” 

Click on the Finish button. 

 

 

 
 

 

Readings and 
Summary is 
displayed. 

Download Wizard Start 
page 

Displays information 
about the iMiniPlus along 
with the date and time 
of the first reading. 

Indicates that the Download was successful. If 

FAILURE 

appears in the Result and there is a 

RED X

 next to in the Description this may 

indicate the iMiniPlus PDF Logger has already 
been programmed. If this is not the case, there is 
a fault with the iMiniPlus and it will need to be 
returned to your distributor.

 

Summary of Contents for iMiniPlus PDF

Page 1: ...iMiniPlus PDF User Guide Version 2 0...

Page 2: ...6 9 3 1 Specification and Alarm 17 9 3 2 LCD Display 18 9 4 Checking the time clock 19 9 5 Setting the Start Stop and logging duration 19 9 5 1 Duration of trip at least 19 9 5 2 Interval between each...

Page 3: ...ning logger data to make a decision on accepting or rejecting the shipment 3 Logger profile The iMiniPlus PDF Logger is available in two models Both have the same temperature range of sensor D range 4...

Page 4: ...your distributor for a replacement When replacing the battery align one triangular mark on the battery cover against similar shaped mark on the logger base to avoid damaging plastic lock feature of th...

Page 5: ...r communication purposes with software LRF file is used by Console Pro to create secure LCF file for traceable data records iMiniPlus PDF Logger does not consume battery power when connected to USB an...

Page 6: ...r of the logger Hardware version this is actually firmware version Description string programmed to the logger by Console Pro Battery status last measured by the logger before it has been connected to...

Page 7: ...d on readings retrieved from logger memory and result may be different Lowest temperature reading for the current trip High Alarm status Low Alarm status Both High and Low Alarm can have the following...

Page 8: ...t to 20 C Note that the graph contains coloured dashed lines for primary alarm limits and solid coloured lines for catastrophe alarm limits Note that the numerical values of the alarm limits are not s...

Page 9: ...trip This part of the report can be disabled when programming You can change date display format to display month first by programming logger Date and Time is displayed along the X axis Temperature v...

Page 10: ...be read as Logger has spent 49 minutes and 40 seconds between 25 C and 25 9 C in this case the value of 1 degree per report line is configured by programmable parameter named Increment Note if Fahrenh...

Page 11: ...ways has two columns This part of the report can be disabled when programming You can change date display format to display month first by programming logger Marked readings are displayed with asteris...

Page 12: ...r The cable has two different ends The smaller one is type Mini B and the bigger one is type A Connect USB cable with Mini B smaller connector to the logger and A size to PC or laptop computer as illu...

Page 13: ...to use Console Pro Professional version 2 12 07 or later to program the logger Check this check box and click on Program and Configure button on the toolbar Program Wizard should start Then click Next...

Page 14: ...report that can be several pages long depending on the number of readings If you uncheck Create PDF file checkbox the logger will not generate PDF report at all You may need this option to prevent unw...

Page 15: ...year format by choosing one option from drop down box on this tab as shown below 9 2 Programming password The iMiniPlus PDF Logger supports a password option that when enabled results in users being...

Page 16: ...to add a password for the first time you can do this here Protect program settings Tick this option if you want to protect your programming settings for the current logger Protect retrieval of reading...

Page 17: ...eturn inside alarm limits the consecutive alarm is reset Total number of out of specification readings cumulative the alarm is triggered if the total number of out of spec readings equals or exceeds t...

Page 18: ...N 4 19 OFF 0 OFF 2 OFF 4 ALARM ON 5 21 OFF 1 OFF 3 OFF 5 ALARM ON 6 22 OFF 2 OFF 4 OFF 7 ALARM ON 7 24 OFF 3 OFF 5 ALARM ON 11 ALARM ON 8 22 OFF 4 ALARM ON 6 ALARM ON 13 ALARM ON 9 21 ALARM ON 5 ALARM...

Page 19: ...ent for instance you have the option of setting up the parameters yourself or let the Console Pro software calculate these automatically for you Thesoftware takes thetotal memory available 8048 readin...

Page 20: ...iMiniPlus PDF Logger User Guide v2 0 20...

Page 21: ...on the LCD You can also enable the STOP button on the logger This is disabled by default because in most applications it is better to take too many readings than too few Downloading the logger readin...

Page 22: ...utton If the upload has failed either select the Cancel button to close the software and start again or select the Restart button to start the sequence again If the iMiniPlus PDF Logger still fails to...

Page 23: ...ve the data from an iMiniPlus PDF Logger both of which will achieve the same result 1 Click the Download Information icon on the toolbar 2 Click the Download Information item located under the Action...

Page 24: ...application Otherwise leave the Logger option at its default setting Do not upload any new start conditions to the logger s Click on the Finish button Readings and Summary is displayed Download Wizard...

Page 25: ...d to communicate with the logger In other words you can email LRF files and Console Pro will create an LCF file from the LRF file Then you will be able to add digital signatures to the LCF file view d...

Page 26: ...n menu The following dialog should be displayed Please ensure that file name is unique By default Console Pro assigns the logger s serial number and trip number to the name of the file Navigate to the...

Page 27: ...and date Real time clock accurate to 1minute per month Sampling frequency 5 seconds 18hours Power source User replaceable 3V lithium coin cell Typical battery life 1 2 years operating life from a user...

Page 28: ...our website www cryopak com http www cryopak com en verification products Mailing Address PO Box 309 Buchanan VA 24066 Office 120 Parkway Drive Buchanan VA 24066 Phone 1 540 254 1433 1 732 346 9200 Ex...

Reviews: