background image

The air/hydraulic pump is capable of generating fluid

pressure up to 10,000 PSI. Make certain the tool in 

use is held securely and is in proper working condition. 

DO NOT continue to operate the pump once the work is 

Completed. Failure to comply with these instructions 

Could result in personal injury or damage to the 

equipment. 

SPECIFICATIONS 

Model 

Input Air 

Pressure 

(psi)

 

Input 

Port 

Threads 

(NPT)

 

Output 

Port 

Threads 

(NPT)

 

Oil Delivery 

(cu.in. /min) 

0 psi    10,000 psi 

Internal 

Relief 

Setting 

(psi)

 

Reservoir 

Capacity

 

Usable Oil 

Capacity 

(cu. in.) 

Weight 

(lbs.)

 

LxWxH 

10875 

90-140

1/4”-18 

3/8”-18 

24.4       7.3 

10,000 

5 Quarts 

185 

24 

12.5x7x7.5 

10876 

90-140

1/4”-18 

3/8”-18 

24.4       7.3 

10,000 

1/2 Gallon 

98 

19 

10.3x5.3x7.3 

10877 

90-140

1/4”-18 

3/8”-18 

24.4       7.3 

10,000 

5 Quarts 

185 

28 

12.5x7x7.5 

DESCRIPTION 

This Air/Hydraulic Pump supplies hydraulic fluid pressure to selected tools. It consists of an in-line air and hydraulic cylinder. The 

ratio of hydraulic fluid pressure generated compared to supply air pressure is 100:1. 

In other words, 100 PSI out for every 1 PSI in – 100 PSI input air pressure equals 10,000 PSI output pressure. 

Depressing the RELEASE pedal causes a decrease in pressure and pressing the PUMP end of the pedal provides fluid pressure. 

WARNING

 

 

 

 

 

 

 

BEFORE USE 

To prevent oil leak during shipment, a metal knob is installed and tightened to ensure the best sealing 

function. Loosen it counterclockwise before use. 

Note: 

Apply Teflon tape to both 3/8” NPT ends of the hydraulic hose. Attach Male coupler to the swivel end of hose and attach the 

non-swivel end of the hose to the hydraulic pump.

WARNING: DO NOT USE ANY HARDENING PIPE THREAD COMPOUND ON THE ENDS OF ANY HYDRAULIC TOOL 

FITTINGS AND/OR CONNECTIONS. USE OF ANY PIPE THREAD HARDENING COMPOUND MAY LEAD TO FAILURE OF 

HYDRAULIC TOOLS AND WILL VOID WARRANTY

1.

Connect the hose of the Air/Hydraulic Pump to the hydraulic coupling on the selected tool.

2.

Connect the air supply line to the Air/Hydraulic Pump. Air supply should be 5-10 CFM at 100 PSI to obtain proper

operating characteristics. In addition, the air line should be equipped with an airline filter.

3.

Stepping on the PUMP end of the pedal engager the pump, producing the force necessary to run the tool.

4.

Depressing the RELEASE end of the pump pedal will release the pressure.

MAINTENANCE 

1.

Inspect hoses and connections daily.

2.

Tighten connections as needed. Use non- hardening pipe thread compound when servicing connections.

3.

Use only good quality hydraulic fluid. We recommend AW- 32 WEIGHT OIL.

When not in use or during storage: 

a.

Depressurize and disconnect hydraulic hoses from application.

b.

Wipe clean, thoroughly.

c.

Store in clean, dry environment. Avoid temperature extremes.

d.

Shield pump with a protective cover.

Adding Hydraulic Fluid 

1.

Depressurize and disconnect hydraulic hose from application.

2.

With pump in it’s upright, horizontal position, remove the oil filler plug located on the top plate of the reservoir.

3.

Use a small funnel to fill reservoir to within 3/4” (19mm) of the opening.

15270 Flight Path Drive • Brooksville, FL 34604

www.esco.net • [email protected]

Phone (352) 754-1117 • Toll Free (800) 352-9852 US, Canada & Caribbean ONLY • Fax (352) 754-4508

Rev. 

0

8

2

1

O

PERATION 

Operation of the unit is as follows: 

WARNING: This product contains chemicals known to the State of California to cause cancer or birth 

defects and/or other reproductive harm. Cancer and Reproductive Harm- www.P65Warnings.ca.gov

Reviews: