background image

ESCO EURO BEAD BREAKER Model #10107 

Purging Air 

These instructions are designed for use with the ESCO Air/Hydraulic Pump.  If using a different 

pump, use this information as a guide only.  Purge air from the pump and bead breaker as 

follows: 

Remove the snap rings on the rod connectors (items 35 and 38 on the parts drawing). 

Connect the air/hydraulic pump to the tool. 

Connect the pump to the air supply. 

Position the pump so that it is higher than the tool and depress the PUMP end of the pedal. 

After the clamping and breaker rods are fully extended, depress the RELEASE end of the 

pedal.  Repeat this cycle (PUMP - RELEASE) about five times. 

Extend both rods and keep them extended.  Check for leaks.  Make certain that the rods do 

not “creep” back into the cylinders. 

Cleaning 

Wash the exterior of the bead breaker with warm, soapy water.  Rinse with clean water and blow 

the tool dry with an air nozzle.  Also pay particular attention to the cleanliness of the pump. 

CAUTION

 

Avoid seal damage.  Do not use solvent to clean the bead breaker. 

Storage 

Prior to storing the bead breaker: 

Completely retract both rods.  An exposed rod may be subject to rusting, pitting and damage 

from striking other tools. 

If chloride is spilled on the tool, rinse with clean water and blow dry. 

Dress rod surface nicks and dents with fine grit emery paper.  Rod surface nicks and dents, 

if left untended, provide a starting point for rust. 

NOTE

The chrome plated rod surfaces provide the seal for the tool.  Any steps taken to ensure the 

continuing quality of the rod surfaces will increase the service life of the tool. 

Summary of Contents for 10107

Page 1: ...EURO BEAD BREAKER MODEL 10107 Instruction Manual Parts Breakdown ...

Page 2: ...c coupling on the bead breaker tool Connect the air supply line to the air hydraulic pump The air supply should be between 5 and 10 CFM at 100 PSI to obtain proper operating characteristics In addition the air line should be equipped with an air line filter 3 Position the bead breaker so that the jaw makes solid contact with the rim and the teeth are positioned in the crevice between the bead of t...

Page 3: ...eter of the rim The tool can be used on the front and back bead areas 7 Once the bead is free of the rim depress the RELEASE end of the pump pedal ESCO EURO BEAD BREAKER Model 10107 Service Most bead breaker malfunctions are a direct result of foreign matter such as dirt dust water etc entering the tool through the open hydraulic coupler union Keep the union clean and capped when the pump is not c...

Page 4: ... leaks Make certain that the rods do not creep back into the cylinders Cleaning Wash the exterior of the bead breaker with warm soapy water Rinse with clean water and blow the tool dry with an air nozzle Also pay particular attention to the cleanliness of the pump CAUTION Avoid seal damage Do not use solvent to clean the bead breaker Storage Prior to storing the bead breaker 1 Completely retract b...

Page 5: ...der Fluid pressure is restricted to the clamping cylinder by spring pressure on the sequence ball and by the mated surfaced of the fluid return ball and its seat As the clamping rod moves out of the cylinder the jaw clamps firmly on the rim The internal hydraulic pressure of the clamping cylinder is sufficient to overcome the spring pressure against the sequence ball The ball is forced away from t...

Page 6: ...crease in pressure in the clamping cylinder With less pressure on the clamping cylinder side of the fluid return ball than on the breaker side the fluid return ball is lifted off the seat and the breaker rod retracts Retraction is due to an internal spring and pressure of the bead against the tongue The breaker rod retracts first followed by the clamping rod NOTE The clamp can be adjusted for diff...

Page 7: ... cylinder is not being released Weak or broken spring in breaker cylinder Replace Air piston stuck Check cylinder bore of pump for contamination or lack of lubrication Pump does not reciprocate Piston poppet not sealing Replace Pump reciprocates Ram will not extend Check prime Depress both air valve and hydraulic release valve at the same time Outlet check ball not sealing properly Correct or repl...

Page 8: ...EURO BEAD BREAKER Model 10107 ...

Page 9: ...Ring 2 12 Seal Ring 2 13 Seal 1 14 O Ring 1 15 Spring 1 16 Spring 1 17 O Ring Thin Ring 1 18 Nut 4 19 Pin 1 20 Spacers 2 21 Clamp Jaw Pin 1 Part Description Qty 22 Washer 1 23 Screw 1 24 Screw 2 25 Valve Plug 1 26 Washer 2 27 Spring 1 28 Sequencing Ball 1 29 Screw 3 30 Washer 3 31 Screw 1 32 Washer 1 33 Ball 1 34 Bolt 1 35 Snap Ring 4 36 Coupler 1 37 T Handle 2 38 Set Screw 1 39 Rubber Inserts 6 4...