KS1150 Peninsula 400
PRODUCT SPECIFICATION
MODEL NAME
KS1150 Peninsula 400
Description of Appliance
Gas Fire Heater
Star Rating
3.9 Stars
AS/NZ Approval Standard
AS/NZS 5263.1.3:2016
Gas Type
Natural Gas
ULPG
Propane
Gas input
High
33 MJ/h
33 MJ/hr
33 MJ/h
Low
24 MJ/h
24 MJ/hr
24 MJ/h
Inlet Pressure
Max
5.0 kPa
5.0 kPa
5.0 kPa
Min
1.13 kPa
2.75 kPa
2.75 kPa
Operating Pressure on High
0.74 kPa
1.5 kPa
1.5 kPa
Operating Pressure on Low
0.34 kPa
0.76 kPa
0.76 kPa
Burner Jet Size
LH & RH: 1.50mm
Middle: 1.95mm
LH & RH: 0.95mm
Middle: 1.25mm
LH & RH: 0.95 mm
Middle: 1.25mm
Burner Aeration
LH & RH: Closed
Collars
Middle: Closed
Collar
LH & RH: 2 x
6mm
Middle: Spacer
(no restriction)
LH & RH: 2 x 6mm
Middle: Spacer
(no restriction)
Pilot injector
#42
#27
#27
Appliance Dimensions (mm)
Width
350 mm
Height
790 mm
Depth
1270 mm
Weight
Kg
120 kg
Ignition System
Electronic Ignition to pilot system
Escea PCB
Ignition Activation
20 secs (approx)
Flame Safeguard
Flame Rectification
Consumption
160W @ 0.69A 230V
Remote controls
Yes
Timers
Yes
Clock
Yes
Function lock / child
Yes
Temperature control
Yes
Connections
Electric 230V AC
Gas 1/2" BSPP female lower centre of fireplace chassis
Flue Type
Aluminium Flexi Flue and PolyPro
Flue Size
75mm and 100mm Flexi Flue & PolyPro
Spigot
Location
Top RH Side
Data badge location
On Chassis Base