2.

 

Installation and Details for Caution Use 

            * Unless you follow the cautions properly, there may be life damage or material damage.   
 

„

 

Correct Installation Procedures 

z

 

This instrument is intended for indoor use only. 

z

 

Install in areas with no influence of heat, such as direct ray of light and heater. 

z

 

Install away from areas with either strong magnetic force or electrical noise. 

z

 

Install on a flat and vibration-free platform. 

z

 

Install in areas with no dusts and moistures. 

z

 

Install in areas with no wind currents and radical thermal alterations. 

z

 

This instrument is not suitable for use at altitude above 2000m.

 

 

„

 

Details for Caution Use – Make sure to check the power source before use.       

z

 

Use a soft cloth with appliance of alcohol when polishing the scale. 

z

 

Keep out water or any liquid-type substance from the scale. 

z

 

Check to see if the scale is placed horizontally before use. If the scale is not in a horizontal position, use the horizontal positioning screw in order to adjust its position. 

      (Have the foam inside of the level gauge be in the center.) 

z

 

When the scale is turned on, the display will be set to initial scaling condition after indicating RB-XX.   

In order to maintain its electrical safeties, warm up the machine for approximately 10 minutes before use. 

z

 

Make sure the weight display is set to " 0 g " before use. If the display is not set to " 0 g ", use after setting the display to " 0 g " by pushing the "Zero/Tare" key. 

z

 

Use only authorized adapter.   

z

 

Use same kinds of batteries when using batteries.   

z

 

Remove the battery from the scale if not using the scale for a long time.    It may cause damage to the scale from the leak of zinc-air battery.   

z

 

Weighing by over maximum capacity may cause damage to the scale.   

z

 

This scale needs periodical inspection every two years.   

z

 

Never reorganize, repair or disassemble this scale.    Inquire of a manufacturer of a distributor about after service.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for E15CB

Page 1: ...CB Series Battery Powered Counting Scales E Es sc ca al li i TM Digital Scales ELECTRONIC SCALE OPERATING MANUAL...

Page 2: ...t DC 1 5V D size X 6EA DC 12V 300mA Adapter Power Consumption MAX 0 31W Platform Size mm 337 W 256 L Product Size mm Non pole type 348 W 382 4 L 153 H Product Weight Non pole type 4 kg Display Two sid...

Page 3: ...ntroduction Thank you for purchasing our Escali commercially applicable CB SERIES electronic scale Before using this product please read the manual carefully in order to fully utilize the features z T...

Page 4: ...le is placed horizontally before use If the scale is not in a horizontal position use the horizontal positioning screw in order to adjust its position Have the foam inside of the level gauge be in the...

Page 5: ...s in the scale 2 Battery D size Open the battery cover Place 6 units of batteries to polarity at the bottom of the scale Close the cover properly Exchange the battery when BAT is indicated in the disp...

Page 6: ...ucts Unit Wt Unit weight Key Sets up the unit weight of the scaled product Q ty Quantity Key Sets up the quantity of the scaled product Add Key Adds up the prices Total Key Shows the total add up pric...

Page 7: ...e tare weight display will show the scaled product weight excluding the container weight Use after resetting the tare when the container weight has been changed Procedures to set to counting 1 procedu...

Page 8: ...15 30 l b e d 0 005 l b 0 01 l b lb Model CB 15N WEIGHT UNITWEIGHT QUANTITY BAT Short Unit Wt TO TAL TARE ZERO Short Q ty kg g pc pcs Reference Unable to delete the inputted unit weight therefore inpu...

Page 9: ...2 Input the unit weight by using the number keys unit weight is 2 g W ei ghi ng r ange 40 g 6 15 kg e d 2 g 5 g 0 1 l b 15 30 l b e d 0 005 l b 0 01 l b lb Model CB 15N WEIGHT UNITWEIGHT QUANTITY BAT...

Page 10: ...WEIGHT UNITWEIGHT QUANTITY BAT Short Unit Wt TO TAL TARE ZERO Short Q ty kg g pc pcs 8 Push the key after removing the scaled product C W ei ghi ng r ange 40 g 6 15 kg e d 2 g 5 g 0 1 l b 15 30 l b e...

Page 11: ...ng up with OFF z Without inputting a key for 5 seconds will automatically set back to the scale mode in the picture No 2 z The scale is dispatched with 5 minutes automatic turning off the power mode T...

Page 12: ...this company or this company s acknowledged business pursuits z Breakdown caused by lack of user s care z Interior remodeling when damage is made by a person not affiliated with this company and this...

Reviews: