Unit 

Specifications 

and Featu

res

 

                                                 

Other Features

• 

Auto-Restart(some units)

If the unit loses power, it will automatically 

restart with the prior settings once power has 

been restored.

• 

Anti-mildew (some units)

When turning off the unit from COOL, AUTO 

(COOL), or DRY modes, the air conditioner will 

continue operate at very low power to dry up 

condensed water and prevent mildew growth.

• 

Wireless Control 

(some units)

Wireless control allows you to control your air 

conditioner using your mobile phone and a 

wireless connection.

• 

Louver Angle Memory(some units)

When turning on your unit, the louver will 

automatically resume its former angle.

• 

Refrigerant Leakage Detection
(some units)

The indoor unit will automatically display “EC” 

or “EL0C”or flash LEDS (model dependent )
when it detects refrigerant leakage.

The SLEEP function is used to decrease
energy use while you sleep (and don’t 
need the same temperature settings to 
stay comfortable). This function can only
be activated via remote control. And the

Sleep function is not available in FAN or

DRY mode. 

Press the 

SLEEP

 button when you are

ready to go to sleep. When in COOL mode, 
the unit will increase the temperature 
by 1°C (2°F) after 1 hour, and will increase 
an additional 1°C (2°F) after another hour. 
When in HEAT mode, the unit will decrease 
the temperature by 1°C (2°F) after 1 hour, 
and will decrease an additional 1°C (2°F)
after another hour.

Sleep Operation

• 

For the USB device access, replacement, 
maintenance operations must be carried 
out by professional staff.

Set 

temperature

1hr

1hr

Keep

running

SLEEP Operation

Saving energy during sleep

Heat mode( -1 C/2 F) 

per hour

for the first two hours

Cool mode(+1 C/2 F) 

per hour

for the first two hours

A guide on using the infrared remote is not 
included in this literature package. 

Not all 

the functions are available for the air
conditioner,  please check the indoor display 
and remote control of the unit you purchased. 

The sleep feature will stop after 8 hours and 
the system will keep running with final 
situation.    

 Page  11 

Unit 

Specifications 

and Featu

res

Manual control button

Setting vertical angle of air flow 

While the unit is on, use the 

SWING/DIRECT

 

button on remote control to set the direction 
(vertical angle) of airflow. Please refer to the 
Remote Control Manual for details.

 

The horizontal angle of the airflow must be set 

manually. Grip the deflector rod (See 

Fig.B

)

and manually adjust it to your preferred direction.

For some units,

 the horizontal angle of the airflow

can be set by  remote control. please refer to the
Remote Control Manual.

NOTE ON LOUVER ANGLES 

When using COOL or DRY mode, do not set 

louver at too vertical an angle for long periods 

of time. This can cause water to condense on 

the louver blade, which will drop on your floor 

or furnishings. 
When using COOL or HEAT mode, setting the 

louver at too vertical an angle can reduce the 

performance of the unit due to restricted air 

flow.

 CAUTION

Do not put your fingers in or near the blower 

and suction side of the unit. The high-speed 

fan inside the unit may cause injury.

Fig. B

Fig. A

Setting Angle of Air Flow

Setting horizontal angle of air flow

• 

 

To operate your unit manually:

1. Open the front panel of the indoor unit.
2. Locate the 

MANUAL CONTROL 

button 

on

the right-hand side of the unit.

3. Press the 

MANUAL CONTROL 

button 

one

time to activate FORCED AUTO mode.

4. Press the 

MANUAL CONTROL button 

again

to activate FORCED COOLING mode.

5. Press the 

MANUAL CONTROL 

button 

a third

time to turn the unit off.

6. Close the front panel.

 CAUTION

The manual button is intended for testing purposes 
and emergency operation only. Please do not use this 
function unless the remote control is lost and it is 
absolutely necessary. To restore regular operation, 
use the remote control to activate the unit. Unit must
be turned off before manual operation.     

Manual Operation(without remote)

Deflector 

rod

Rang

e

NOTE:

 Do not move louver by hand. This will 

cause the louver to become out of sync. If this 
occurs, turn off the unit and unplug it for a few
seconds, then restart the unit. This will reset the 
louver.   

Summary of Contents for ESAC25RC

Page 1: ...rManual Exactly what you need Model Code s ESAC25RC ESAC35RC ESAC50RC Online esatto house Product 2 5kW Split System Air Conditioner 3 5kW Split System Air Conditioner 5 0kW Split System Air Condition...

Page 2: ...mportantly taking care of the appliance our Support Team are here to help You can use our online Support Centre at anytime by visiting http support residentiagroup com au Or you can contact us via pho...

Page 3: ...essories Page 20 Installation Summary Indoor Page 21 Unit Parts Page 22 Indoor Unit Installation Page 28 Outdoor Unit Installation Page 32 Refrigerant Piping Connection Page 35 Air Evacuation Page 37...

Page 4: ...4 Safety This page is intentionally left blank...

Page 5: ...ises like a burning smell immediately turn off the unit and disconnect the power Call your dealer for instructions to avoid electric shock fire or injury Do not insert fingers rods or other objects in...

Page 6: ...share the electrical outlet with other appliances Improper or insufficient power supply can cause fire or electrical shock If connecting power to fixed wiring an all pole disconnection device which ha...

Page 7: ...install the appliance to its support please read the information for details in indoor unit installation and outdoor unit installation sections For units that have an auxiliary electric heater do not...

Page 8: ...chanical connectors are reused indoors sealing parts shall be renewed When flared joints are reused indoors the flare part shall be re fabricated IEC Standard Requirements European Disposal Guidelines...

Page 9: ...when TIMER ON is set FRESH SWING TURBO SILENCE or SOLAR PV ECO feature is turned on for 3 seconds when TIMER OFF is set FRESH SWING TURBO SILENCE or SOLAR PV ECO feature is turned off when defrosting...

Page 10: ...TURBO or SILENCE features is turned off when defrosting for cooling heating units when unit is self cleaning some units when fresh feature is turned on some units when ECO feature is activated some un...

Page 11: ...22 F 15 C 24 C 5 F 75 F 0 C 50 C 32 F 122 F 0 C 52 C 32 F 126 F For special tropical models 0 C 52 C 32 F 126 F For special tropical models 15 C 50 C 5 F 122 F For models with low temp cooling systems...

Page 12: ...settings to stay comfortable This function can only be activated via remote control And the Sleep function is not available in FAN or DRY mode Press the SLEEP button when you are ready to go to sleep...

Page 13: ...gers in or near the blower and suction side of the unit The high speed fan inside the unit may cause injury Fig B Fig A Setting Angle of Air Flow Setting horizontal angle of air flow To operate your u...

Page 14: ...o be bad for your health Make sure to clean the filter once every two weeks 1 Lift the front panel of the indoor unit 2 Grip the tab on the end of the filter lift it up then pull it towards yourself 3...

Page 15: ...e If you plan not to use your air conditioner for an extended period of time do the following Clean all filters Turn on FAN function until unit dries out completely Turn off the unit and disconnect th...

Page 16: ...s Troubleshooting Troubleshooting The unit changes from COOL HEAT mode to FAN mode The indoor unit makes noises A rushing air sound may occur when the louver resets its position A squeaking sound may...

Page 17: ...t customer service center Provide them with a detailed description of the unit malfunction as well as your model number Troubleshooting Troubleshooting When troubles occur please check the following p...

Page 18: ...Poor heating performance The outdoor temperature is extremely low Use auxiliary heating device Cold air is entering through doors and windows Make sure that all doors and windows are closed during use...

Page 19: ...Shape Quantity PC Need to be installed on the back of main air filter by the authorized technician while installing the machine Mounting plate fixing screw Remote controller Fixing screw for remote c...

Page 20: ...Mounting Plate Determine Wall Hole Position 1 2 3 Drill Wall Hole 4 12cm 4 75in 2 3m 90 55in 12cm 4 75in 15cm 5 9in Mount Indoor Unit STEP 8 Wrap Piping and Cable not applicable for some locations in...

Page 21: ...e requirement of local and national standards The installation may be slightly different in different areas Wall Mounting Plate Power Cable Some Units Refrigerant Piping Signal Cable Remote Controller...

Page 22: ...direct sunlight NOTE ABOUT WALL HOLE If there is no fixed refrigerant piping While choosing a location be aware that you should leave ample room for a wall hole see Drill wall hole for connective pipi...

Page 23: ...ure to avoid wires plumbing and other sensitive components Type A Type B 101mm 4in 179mm 7 05in 136mm 5 35in 37mm 1 45in 290mm 11 4in 49mm 1 95in Right rear wall hole 65mm 2 5in Indoor unit outline 72...

Page 24: ...k out Panel CAUTION Be extremely careful not to dent or damage the piping while bending them away from the unit Any dents in the piping will affect the unit s performance Step 5 Connect drain hose By...

Page 25: ...rmly connected Loose wiring can cause the terminal to overheat resulting in product malfunction and possible fire Do not let wires touch or rest against refrigerant tubing the compressor or any moving...

Page 26: ...l on the back DRAIN HOSE MUST BE ON BOTTOM Make sure that the drain hose is at the bottom of the bundle Putting the drain hose at the top of the bundle can cause the drain pan to overflow which can le...

Page 27: ...pressure to the left and right hand sides of the unit The unit should not jiggle or shift 6 Using even pressure push down on the bottom half of the unit Keep pushing down until the unit snaps onto th...

Page 28: ...wind If needed build a barrier in front of the unit to protect it from extremely heavy winds See Figures below Strong wind Strong wind Strong wind If the unit is frequently exposed to heavy rain or s...

Page 29: ...ubber seal see Fig B do the following 1 Insert the drain joint into the hole in the base pan of the unit The drain joint will click in place 2 Connect a drain hose extension not included to the drain...

Page 30: ...ce a nut on the end of each expansion bolt 4 Hammer expansion bolts into the pre drilled holes 5 Remove the nuts from expansion bolts and place outdoor unit on bolts 6 Put washer on each expansion bol...

Page 31: ...clamp down tightly 7 Insulate unused wires with PVC electrical tape Arrange them so that they do not touch any electrical or metal parts 8 Replace the wire cover on the side of the unit and screw it i...

Page 32: ...er than the specified refrigerant enter the unit The presence of other gases or substances will lower the unit s capacity and can cause abnormally high pressure in the refrigeration cycle This can cau...

Page 33: ...rrs from falling into the pipe 2 Using a reamer or deburring tool remove all burrs from the cut section of the pipe Pipe Reamer Point down Step 3 Flare pipe ends Proper flaring is essential to achieve...

Page 34: ...7 0 76 0 78 23 2 23 7 0 91 0 93 18 20 180 200kgf cm 32 39 320 390kgf cm 49 59 490 590kgf cm 57 71 570 710kgf cm 67 101 670 1010kgf cm 9 52 0 375 12 7 0 5 16 0 63 19 0 75 1 Unscrew the cover from the p...

Page 35: ...m for at least 15 minutes or until the Compound Meter reads 76cmHG 10 Pa 2 3 4 5 5 6 Close the Low Pressure side of the manifold gauge and turn off the vacuum pump 7 Wait for 5 minutes then check that...

Page 36: ...00Btu h and 24000Btu h ADDITIONAL REFRIGERANT PER PIPE LENGTH Connective Pipe Length m Air Purging Method Additional Refrigerant Standard pipe length Vacuum Pump N A Standard pipe length Vacuum Pump L...

Page 37: ...Method Using a soft brush apply soapy water or liquid detergent to all pipe connection points on the indoor unit and outdoor unit The presence of bubbles indicates a leak Leak Detector Method If using...

Page 38: ...pressure of the refrigerant circuit will increase This may reveal leaks that were not present during your initial leak check Take time during the Test Run to double check that all refrigerant pipe con...

Page 39: ...specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service w...

Page 40: ...details of your purchase below and staple your receipt on the opposite page Your serial number can be found on the Rating Label which is applied to your unit STORE DETAILS STORE NAME ADDRESS TELEPHON...

Page 41: ...41 Attach your receipt to this page...

Page 42: ...during the Warranty Period g Warranty Period means i where the Appliance is used for personal domestic or household use i e normal single family use as set out in the instruction manual the Appliance...

Page 43: ...g from your purchase use or non use of the Appliance 10 For Appliances and services provided by Residentia Group in Australia the Appliances come with a guarantee by Residentia Group that cannot be ex...

Page 44: ...This page is intentionally left blank Appliances Exactly what you need A RESIDENTIA GROUP INITIATIVE...

Reviews: