esatto.house
15
Technical Data
Note:
1. The rated capacity is the maximum capacity, make sure
that the dry clothes which are loaded to the appliance
do not exceed the rated capacity each time.
2. Do not install the tumble dryer in a room when there is a
risk of frost occurring. At temperatures around freezing
point the tumble dryer may not be able to operate
properly.
3. There is a risk of damage if the condensed water
is allowed to freeze in the pump, hoses and / or
condensed water container.
19
20
MAINTENANCE
MAINTENANCE
•Clean lint filter and wash condenser.
•Empty container.
•Check water outlet.
•Dryer installation too restricted.
•Clean the moisture sensors.
•Use next higher drying programme or using
Timer programme.
•Check the clothes is over load .
Problem
Solution
•Working state LED
not on
•The mains plug is inserted.
•Check the programme selected.
•Check fuse in the house.
•Empty condensation container.
•If failure, check hose for condensation outlet.
•Dryer does not start
•Check the
has selected
•Check the the door has closed.
•Check the programme has set.
start button
.
•Water is running out
•Align dryer horizontally.
•Clear air condenser and door seals.
•Door is open by itself
•Press door until it “clicks”into position.
•Degree of dryness was
reached or drying time too
long
not
•Humidity in the room is
increase significantly
•Ventilate room adequately.
•Clean the cool grille.
•Ensure that the air condenser has been inserted.
•
“Full” LED on permanently
If you cannot deal with the fault by yourself and need help:
• Press the
【
On/Off
】
button
.
• Pull out
the mains plug and call the service
.
Warning!
!
•
The rated capacity is the maximum capacity, make sure that the dry clothes which are
loaded to the appliance do not exceed the rated capacity each time.
•
Do not install the tumble dryer in a room when there is a risk of frost occurring. At
temperatures around freezing point the tumble dryer may not be able to operate
properly.
•
There is a risk of damage if the condensate water is allowed to freeze in the pump,
hoses and / or condensate water container.
+
5
°
c
~
+35
°
c
Technical
Specifications
220-240V~
Rated capacity
Rated frequency
Dimension(L*W*H)
Rated input power
Rated voltage
622*595*845(mm)
850W
Weight of product
51kg
7.0kg
50Hz
Model
Parameter
MDS70-CH05/B08-AU(6)
Ambient temperature
+
5
°
c
~
+35
°
c
220-240V~
622*595*845(mm)
2000W
41kg
7.0kg
50Hz
Note!
MDS70-C05/B08-AU(2)
Refrigerant
R134a
Contains fluorinated greenhouse gases covered by the Kyoto Protocol.
Hermetically sealed.
EHPD7
ECD7