background image

Be sure this information reaches the operator.

You can get extra copies through Your supplier.

saVe these instructions!

important safeguarDs

When using Oxy-Fuel Gas Torches, basic safety precautions should always be followed:

Never use Acetylene gas at a pressure over 15 psig.

a. 

Never use damaged equipment.

b. 

Never use oil or grease on or around Oxygen equipment.

c. 

Never use Oxygen or fuel gas to blow dirt or dust off clothing or equipment.

d. 

Never light a torch with matches or a lighter.  Always use a striker.

e. 

Always wear the proper welding goggles, gloves and clothing when operating Oxy-Acetylene equipment.  

f. 

Pants should not have cuffs.

Do not carry lighters, matches or other flammable objects in pockets when welding or cutting.

g. 

Always be aware of others around you when using a torch.

h. 

Be careful not to let welding hoses come into contact with torch flame or sparks from cutting.

i. 

SAVE THESE INSTRUCTIONS.

j. 

This equipment will perform in conformity with the description thereof contained in this manual and accompa-

nying labels and/or inserts when installed, operated, maintained and repaired in accordance with the instruc-

tions provided.  This equipment must be checked periodically.  Malfunctioning or poorly maintained equipment 

should not be used.  Parts that are broken, missing, worn, distorted or contaminated should be replaced imme-

diately.  Should such repair or replacement become necessary, the manufacturer recommends that a telephone 

or written request for service advice be made to the Authorized Distributor from whom it was purchased.

This equipment or any of its parts should not be altered without the prior written approval of the manufacturer.  

The user of this equipment shall have the sole responsibility for any malfunction which results from improper 

use, faulty maintenance, damage, improper repair or alteration by anyone other than the manufacturer or a ser-

vice facility designated by the manufacturer.

these instructions are for experienced operators.  if you are not fully familiar with the prin-

ciples of operation and safe practices for gas welding and cutting equipment, we urge you to read 

our booklet, “precautions and safe practices for gas Welding, cutting, and heating,” form f-2035.  

Do not permit untrained persons to install, operate, or maintain this equipment.  Do not attempt 

to install or operate this equipment until you have read and fully understand these instructions.  if 

you do not fully understand these instructions, contact your supplier for further information.  Be 

sure to read the safety precautions  before installing or operating this equipment.

caution

user responsiBilitY

reaD anD unDerstanD instruction manual Before installing 

or operating.  protect Yourself anD others!

Summary of Contents for OXWELD C-62

Page 1: ... cylinder valve open the corre sponding torch valve to remove all pressure from the line and finally release the regulator pressure adjusting screw by turning it counterclockwise Then break the leaky con nection wipe metal seating surfaces with a clean dry cloth and examine them for nicks and scratches Re make the connection s and retest Do not try to light the torch until you are satisfied that a...

Page 2: ...ed Parts that are broken missing worn distorted or contaminated should be replaced imme diately Should such repair or replacement become necessary the manufacturer recommends that a telephone or written request for service advice be made to the Authorized Distributor from whom it was purchased This equipment or any of its parts should not be altered without the prior written approval of the manufa...

Page 3: ...ve stem assembly from the torch With a clean cloth wipe the ball in the end of the stem Then reinsert valve stem assembly and tighten it several times with maximum force If this does not eliminate leakage try a new valve stem assembly If then the valve does not shut off completely send the torch to a repair station for reseating of the body After installing a new valve stem assembly tighten the pa...

Page 4: ...ecommended in the charts on page 4 or OXWELD nozzle cleaning com pound To clean the preheat slots on internal nozzles remove the external sleeve and use a soft bristled brush For longer life nozzles should be cleaned periodically in a solution of OXWELD nozzle cleaning compound Part No 761F00 made up and used as directed on the jar in which it is packed Cutting Valve Lever To remove merely drive o...

Page 5: ... 1 4 1524 SERIES 10 preheat holes 25 15X51 5190070 5190062 1520 SERIES 10 preheat holes 13 15X33 5190068 5190071 19 15X34 5190069 5190072 25 15X35 5190070 5190062 1539 SERIES 10 preheat holes 19 65Z55 55 Drill 3 16 Drill 25 65Z56 53 1 4 1534 SERIES 2 piece slotted preheats Part No Cleaning Size Internal External Tool Cutting 2 14Z66 14Z38 76 Drill 3 14Z50 14Z38 68 4 14Z51 14Z38 60 6 14Z52 14Z39 53...

Page 6: ...5 POWDER TUBE 147Z25 INSERT 73Z86 SOFT SOLDER DIAPHRAGM 30Z55 1 8 27 NPT STEM SEAT 33Y46 PARTS SUPPLIED WITH 55Y49 4789 NIPPLE 36Z40 NUT SECTION B B SILVER SOLDER RING 38Z68 NUT 37Z25 CAP 31Z57 PIN 38Z34 SPRING 28Z20 POWDER VALVE ASSEMBLY TYPE ACV 2 55Y49 SEE VIEW A FOR REPLACEMENT PARTS SILVER SOLDER 5 8 18 POWDER INLET TUBE 61Y53 3 16 24 2 WASHER 73Z98 CONNECTION 185W04 INCLUDES FERRULE 185W35 1...

Page 7: ...7 ...

Page 8: ... Authorized Repair Stations C TECHNICAL SERVICE Telephone 800 ESAB 123 Fax 803 664 4452 Part Numbers Technical Applications Hours 8 00 AM to 5 00 PM EST Performance Features Technical Specifications Equipment Recommendations D LITERATURE REQUESTS Telephone 803 664 5524 Fax 803 664 5548 Hours 8 30 AM to 5 00 PM EST E WELDING EQUIPMENT REPAIRS Telephone 803 664 4469 Fax 803 664 5557 Repair Estimates...