![ESAB Origo Mag C140 Instruction Manual Download Page 5](http://html1.mh-extra.com/html/esab/origo-mag-c140/origo-mag-c140_instruction-manual_2425101005.webp)
-- 5 --
MC1425e
3
INTRODUCTION
Origo
TM
Mag C140/C150/C170/C200/C250
are step controlled power sources in a compact design,
intended for welding with solid steel, stainless steel or aluminium wire as well as tubular wire with or
without shielding gas.The possibility of welding with homogeneous wire/shielding gas and welding with
gasless tubular wire is obtained by switching the + and -- connections on the switching terminal by the
wire feed unit.
ESAB’s accessories for the product can be found on page 23.
3.1
Equipment
The power source is supplied with:
S
Welding gun
S
Return cable with return clamp
S
Shelf for gas cylinder
S
Instruction manual
4
TECHNICAL DATA
Origo
TM
Mag C140
Origo
TM
Mag C150
Origo
TM
Mag C170
Voltage
220--230V, 1
∼
50/60Hz
220--230V, 1
∼
50/60Hz
220--230V, 1
∼
50/60Hz
Permissible load at
100% duty cycle
42A/16,1V
67A/17,4V
76A/17,8V
60 % duty cycle
54A/16,7V
86A/18,3V
98A/18,9V
@ % duty cycle
67A/17,4V @ 40%
95A/18,7V @ 50%
150A/21,8V @ 25%
20 % duty cycle
100A/13,0V
150A/13,8V
170A/19,3V
Setting range (DC)
35A/15,7V--67A/17,4V
(100A/13,0V)
35A/15,7V--95A/18,7V
(150A/13,8V)
30A/15,5V--150A/19,3
V (170A/19,3V)
Open circuit voltage
19,6--27,5V
18,5--30,5V
15,5--30,6V
Open circuit power
90W
100W
145W
Power factor
at max load
0,92
0,91
0,90
Control voltage
220--230V, 50/60Hz
220--230V, 50/60Hz
42V, 50/60Hz
Wire feed speed
2,0--14m/min
2,0--14m/min
1,0--17m/min
Burnback time
--
--
0,02--0,25s
Spot welding
--
--
0,2--2,5s
Welding gun connection
fixed
fixed
EURO
Wire dimension range
0,6--0,8(Fe)
0,8(cored)
0,8(CuSi)
0,6--0,8(Fe)
0,8(cored)
0,8(CuSi)
0,6--0,8(Fe)
1,0(Al)
0,8(cored)
0,8--1,0(CuSi)
Max diameter/weight
of wire bobin
200mm/5kg
200mm/5kg
300mm/15kg
Dimensions lxwxh
650x300x550
650x300x550
860x420x730
Weight
25kg
37,5kg
59kg
Operating temperature
--10
÷
+40
o
C
--10
÷
+40
o
C
--10
÷
+40
o
C
GB
Summary of Contents for Origo Mag C140
Page 8: ...8 MC1425e 5 2 2 OrigoTM Mag C150 1 3 2 GB...
Page 9: ...9 MC1425e 5 2 3 OrigoTM Mag C170 C200 C250 1 3 2 5 3 Electrical installation GB...
Page 15: ...Diagram 15 dC1425 OrigoTM Mig C140 230V...
Page 16: ...16 dC1425 OrigoTM Mig C150 230V...
Page 17: ...17 dC1425 OrigoTM Mig C170 230V...
Page 18: ...18 dC1425 OrigoTM Mig C200 230V...
Page 19: ...19 dC1425 OrigoTM Mig C250 230V...
Page 24: ...24 hints...
Page 25: ...25 hints...
Page 26: ...26 hints...
Page 27: ...27 hints...
Page 28: ...28 hints...