-- 8 --
MM215Pe
Welding voltage polarity
Welding voltage polarity may be changed as shown below.
5.3
Mains power supply
Check that the unit is connected to the correct mains power supply voltage, and that
it is protected by the correct fuse size. A protective earth connection must be made,
in accordance with regulations.
Rating plate with supply connection data
Migmaster 215 Pro
Migmaster 215 Pro
Voltage V
208/230V, 1
∼
50/60Hz
208/230/460/575V, 1
∼
50/60Hz
Current A
at 100% duty cycle
19/17
19/17/9/7
at 60% duty cycle
30/27
30.5/27.5/14/11
at 20% duty cycle
56/50
58/53/26/21
Cable area AWG
3 x 10
3 x 10
Fuse
slow
A
35
35/35/20/16
GB