-- 37 --
claw0de1
TECHNICAL DATA
LAW 410/410W
LAW 400/400W
400 -- 415 V
LAW 410/410W
LAW 400/400W
230 -- 500 V
LAW 510/510W
LAW 500/500W
400 -- 415 V
LAW 510/510W
LAW 500/500W
230 -- 500 V
Mains voltage
400--415V 3
~
50Hz
230/400--415/500V
3
~
50Hz
230/440--460V
3
~
60Hz
400--415V 3
~
50Hz
230/400--415/500V
3
~
50Hz
230/440--460V
3
~
60Hz
Load capacity
At 45% duty cycle
400A/34V
400A/34V
At 60% duty cycle
350A/32V
350A/32V
500A/39V
500A/39V
At 80% duty cycle
450A/37V
435A/36V
At 100% duty cycle
280A/28V
280A/28V
400A/34V
390A/33.5V
Operating range
60A/17V--400A/34V
60A/17V--400A/34V
60A/17V--500A/39V
60A/17V--500A/39V
Open--circuit voltage
53--58V
53--58V
53--60V
53--60V
Open--circuit power
590/790W
640/840W
670/870W
720/920W
Power factor
0.86
0.84
0.90
0.90
Efficiency
0.74
0.76
0.78
0.78
Control voltage
42V 50/60Hz
42V 50/60Hz
42V 50/60Hz
42V 50/60Hz
Enclosure class
IP 23
IP 23
IP 23
IP23
Electrical protection class
Weight
200/214kg
201/215kg
225/239kg
227/241kg
Dimensions l x b x h
800x640x835mm
800x640x835mm
800x640x835mm
800x640x835mm
These welding power units fulfil the requirements of IEC 974--1
The
S
symbol indicates that the power units have been designed for use in areas of elevated electrical danger.
Units of Class
IP 23
are intended for indoor and outdoor use.
PRIMARY CURRENT, MAINS FUSE RATING AND MAINS CABLE CROSS--SECTIONAL AREA
LAW 400/410
* 400--415V
400--415V
50Hz
** 230--500V
230V
50Hz
** 230--500V
400--415V
50Hz
** 230--500V
500V
50Hz
** 230--500V
230V
60Hz
** 230--500V
440--460V
60Hz
Primary current at:
45% duty cycle
31A
51A
31A
25A
51A
30A
60% duty cycle
28A
47A
28A
22A
45A
27A
100% duty cycle
23A
39A
23A
19A
37A
22A
Cable CSA mm
2
4x4
4x10
4x4
4x4
4x10
4x4
Fuse rating, slow blow
25A
35A
25A
20A
35A
20A
LAW 500/510
* 400--415V
400--415V
50Hz
** 230--500V
230V
50Hz
** 230--500V
400--415V
50Hz
** 230--500V
500V
50Hz
** 230--500V
230V
60Hz
** 230--500V
440--460V
60Hz
Primary current at:
60% duty cycle
42A
69A
42A
31A
69A
42A
80% duty cycle
38A
63A
38A
29A
61A
37A
100% duty cycle
34A
59A
34A
27A
56A
33A
Cable CSA mm
2
4x6
4x16
4x6
4x6
4x16
4x6
Fuse rating, slow blow
35A
63A
35A
35A
50A
25A
*
= Power unit suitable only for a single supply voltage, 400--415V 50Hz.
**
= Power unit suitable for various supply voltages.
Summary of Contents for LAW 400
Page 1: ...0740 800 025 9708 LAW 400 500 LAW 410 510 Welding rectifier Service manual...
Page 6: ...claw0e CONNECTION DIAGRAM LAW 400 500 400 415 V Valid for machine number 434 6 claw0de1...
Page 14: ...14 claw0de1...
Page 17: ...17 claw0de1 AP1 COMPONENT POSITIONS Circuit board with part no 0486 480 880 version A...
Page 30: ...30 claw0de1 AP2 SUPPRESSION CIRCUIT BOARD Circuit diagram Component positions...
Page 45: ...claw0p01 118 claw0p21 119 SPARE PARTS LIST LAW 400 500 45 claw0se1...
Page 47: ...SPARE PARTS LIST LAW 400 500 47 claw0se1 223...
Page 49: ...SPARE PARTS LIST LAW 400 500 49 claw0se1 claw0p03 324 317 325...
Page 54: ...54 page...
Page 57: ...SPARE PARTS LIST LAW 410 510 57 claw0se2 claw0p01 118 claw0p21 119...
Page 59: ...SPARE PARTS LIST LAW 410 510 59 claw0se2 223...
Page 61: ...SPARE PARTS LIST LAW 410 510 61 claw0se2 claw0p03 324 317 325...
Page 63: ...SPARE PARTS LIST LAW 410 510 63 claw0se2 claw0p04 420 415 421 416 421 416 414 419...