In addition to the features already described, the processor performs the following
functions :
S
Frequency measurement
Measures the mains frequency when the unit is turned on. If the frequency is
either 50
¦
4 Hz or 60
¦
4 Hz, the processor starts the main program. If the
frequency is not within the tolerances, the main program that controls the
machine will not start.
S
Voltage monitoring
By sensing that the power supply, +12 V, to the main electronics board is
present, the processor monitors the power supply to the board. If the supply is
lost, the main program stops. When the supply returns, the program starts. See
’Frequency measurement’, above.
S
Overload protection
The LAW 400/410 and LAW 500/510 have average current limits, known as
slow overload trips, at 412 A and 516 A respectively.
S
Short--circuit protection
Both machines incorporate short--circuit protection (fast current trip),
set at 750 A.
S
Firing pulses
The processor generates firing pulses as required by the set welding voltage.
Pulses are duplicated in order to prevent any misfiring of the thyristors.
S
Display management
The processor supplies information on the welding voltage and welding current
to the digital display instrument.
S
Crater filling
Reduces the arc voltage when the wire feed unit calls for crater filling.
S
Test routine
Controls the test routines, described on page 31.
S
Elevated starting voltage (Hot Start)
Applies to machines with serial numbers 512 . . . . . . . and above:
These machines are supplied with controlled thyristor firing angle in operation.
With this arrangement, the starting voltage in the LAW 400/410 is 30% higher
than the set voltage, and in the LAW 500/510 is 20% higher than the set
voltage. Arc voltage control comes into operation 300 ms (50 ms when
pulsing) after the arc strikes, which reduces the arc voltage to the set value. If
the machine is operating with a fixed thyristor firing angle, the hot start feature
is inactive.
Machines with serial numbers 434 . . . . . . . and circuit board 0486 220 880:
These machines can be operated only with a fixed firing angle.
Starting voltages are as follows:
If the set value of arc voltage is less than 21 V, starting voltage will be 20%
higher. If the set value of arc voltage is over 21 V, starting voltage will be 50%
higher. The elevated starting voltage ceases 100 ms after starting.
For these machines there is an exchange circuit board available, E486 220 882,
which has controlled thyristor firing angle and the same starting voltages as
circuit board 0486 291 880.
Summary of Contents for LAW 400
Page 1: ...0740 800 025 9708 LAW 400 500 LAW 410 510 Welding rectifier Service manual...
Page 6: ...claw0e CONNECTION DIAGRAM LAW 400 500 400 415 V Valid for machine number 434 6 claw0de1...
Page 14: ...14 claw0de1...
Page 17: ...17 claw0de1 AP1 COMPONENT POSITIONS Circuit board with part no 0486 480 880 version A...
Page 30: ...30 claw0de1 AP2 SUPPRESSION CIRCUIT BOARD Circuit diagram Component positions...
Page 45: ...claw0p01 118 claw0p21 119 SPARE PARTS LIST LAW 400 500 45 claw0se1...
Page 47: ...SPARE PARTS LIST LAW 400 500 47 claw0se1 223...
Page 49: ...SPARE PARTS LIST LAW 400 500 49 claw0se1 claw0p03 324 317 325...
Page 54: ...54 page...
Page 57: ...SPARE PARTS LIST LAW 410 510 57 claw0se2 claw0p01 118 claw0p21 119...
Page 59: ...SPARE PARTS LIST LAW 410 510 59 claw0se2 223...
Page 61: ...SPARE PARTS LIST LAW 410 510 61 claw0se2 claw0p03 324 317 325...
Page 63: ...SPARE PARTS LIST LAW 410 510 63 claw0se2 claw0p04 420 415 421 416 421 416 414 419...