FAULT FINDING
0464 523 010
- 19 -
© ESAB AB 2016
Fault finding indications
Description
Indication on display
Over temperature
The duty cycle is exceeded.
The over temperature LED is lit and the Volt
display shows "tEm".
Action:
Refer to section "The over tempetature LED
is blinking".
Short circuit
A PCB is short circuited.
The display shows "CC".
Action:
Refer to section "Fault indication "CC" when
torch trigger is pushed".
Trigger alarm
The power source is turned on with the torch
trigger pushed.
The over temperature LED is lit, the Volt
display shows "tri" and the Ampere display
shows "ALA".
Action:
•
Turn off the power source completely.
•
Make sure that the torch trigger is not
pushed.
•
Check if the torch trigger is damaged.
•
Turn on the power source again.