FAULT FINDING
0464 523 010
- 13 -
© ESAB AB 2016
3. Turn off the power source.
Disconnect the mains power supply and wait for five minutes.
a) Measure the diodes on PCB9 and PCB11. Use a multimeter in diode test mode.
Value should be 300 to 400 mV.
Not possible to adjust current with the encoder
Symptom
The power source is turned on and all the LEDs are ok. There is open circuit voltage (OCV)
but it is not possible to adjust the current with the encoder knob.