Error
Code
Severity
Level
Functional Circuit Failure Explanation
005 –
007
(reserved)
008
C
OCV error, Output voltage not sensed at Control Board CN1 as
expected
009
W
Low Voltage Error, AC Mains voltage is less than 108 V AC, this
could trip Err 003
010
(reserved)
011
C
User has attempted a parameter or factory reset, and this was not
confirmed by the system.
012
C
Communication Link Down, no communication between UI and Ctrl
PCB at CN6
013
C
Low Internal Power Supply (IPS) Voltage Error, +24 V IPS is less
than 22 V DC
014
C
Secondary Current Sensor output not detected at Control PCB CN18
015 –
019
(reserved)
020
C
No Image found in Flash
021
C
The image read from the flash is corrupted
022
NC
Failed two attempts of saving user memory to permanent memory in
SPI Flash.
023
NC
Failed two attempts of recovering user memory permanent memory
from SPI Flash.