7 MAINTENANCE
0463 605 001
- 47 -
© ESAB AB 2018
7.3
EMP-unit power side maintenance
NOTE!
There are no user-serviceable parts on the power-side. In dusty environments, the
power-side should be checked periodically for any dust/debris accumulation because
of the fan forced-air cooling used on this side.
Because of the electro-static sensitive components and exposed circuit boards any
maintenance on this side should be done by an authorized ESAB service technician.
7.4
Torch liner maintenance
Refer to MIG torch instruction manual (0458 870 *01) for replacing standard steel torch
conduit liner with a Teflon torch conduit liner.
• Model EMP 255ic uses torch model: PSF 305
• Model EMP 320ic uses torch model: PSF 305
7.4.1
Torch liner cleaning
1.
Disconnect the power source from the input power socket.
2.
Disconnect the torch assembly from the unit.
3.
Remove the wire from the torch wire-liner by pulling the wire out from the torch
wire-liner and laying it neatly for re-installation at the end of this procedure.
4.
Remove the liner from the torch hose and inspect it for damage or kinks. Clean the
liner by blowing compressed air (max. 5 bar) through the end of the liner that was
mounted closest to the unit.
5.
Re-install the liner.
6.
Re-install the wire through the wire-feed assembly until visible at the torch tip. Verify
that the wire does correctly feed out of the torch.