4 INSTALLATION
0463 703 001
GB
-20-
4.6
Recommended electrical-supply specifications
!
!
WARNING!
An electrical shock or fire hazard is probable if the following electrical service guide
recommendations are not followed. These recommendations are for a dedicated branch
circuit sized for the rated output and duty cycle of the welding power source.
Recommended electrical supply specifications: 120–230 V, 1 – 50/60 Hz
Specification
230 V AC
120 V AC
Input current at maximum output
33 A
30 A
Maximum recommended fuse* or circuit breaker rating
*Time delay fuse UL class RK5, refer to UL 248
40 A
30 A
Maximum recommended fuse* or circuit breaker rating
Normal operating UL class K5, refer to UL 248
50 A
50 A
Minimum recommended cord size
2.5 mm2 (13 AWG)
2.5 mm2 (13 AWG)
Maximum recommended extension cord length
15 m (50 ft)
8 m (25 ft)
Minimum recommended grounding conductor size
2.5 mm2 (13 AWG)
2.5 mm2 (13 AWG)
4.7
Supply from power generators
The power source can be supplied from different types of generators. However, some generators may not provide sufficient
power for the welding power source to operate correctly.
Generators with Automatic Voltage Regulation (AVR) or with equivalent or better type of regulation, with rated power of
minimum 8 kW 1 phase, are recommended.