3 TECHNICAL DATA
0463 703 001
GB
-14-
3 TECHNICAL DATA
3.1
EMP 205ic AC/DC specifications
EMP 205ic AC/DC
Voltage
230 V,1 ph, 50/60 Hz
120 V, 1 ph, 50/60 Hz
Primary current
I
max.
GMAW - MIG
29.6 A
Breaker 20 A: 27.1 A
Breaker 15 A: 20.2 A
I
max.
GTAW - DC TIG
24.0 A
Breaker 15 A: 20.7 A
I
max.
GTAW - AC TIG
26.5 A
Breaker 15 A: 21.4 A
I
max.
SMAW - Stick
28.3 A
Breaker 15 A: 20.5 A
I
eff.
GMAW - MIG
14.8 A
Breaker 20 A: 15.8 A
Breaker 15 A: 14.5 A
I
eff.
GTAW - DC TIG
12 A
Breaker 15 A: 14.3 A
I
eff.
GTAW - AC TIG
13.3 A
Breaker 15 A: 14.9 A
I
eff.
SMAW - Stick
14.1 A
Breaker 15 A: 14.4 A
Permissible load in GMAW - MIG
100% duty cycle*
110 A (V
out
= 19.5 V)
Breaker 15 A: 65 A (V
out
= 17.25 V)
Breaker 20 A: 70 A (V
out
= 17.5 V)
60% duty cycle*
125 A (V
out
= 20.25 V)
Breaker 15 A: 85 A (V
out
= 18.25 V)
Breaker 20 A: 90 A (V
out
= 18.5 V)
40% duty cycle*
150 A (V
out
= 21.5 V)
Breaker 15 A: 90 A (V
out
= 18.5 V)
25% duty cycle*
205 A (V
out
= 24.25 V)
-
20% duty cycle*
-
Breaker 20 A: 115 A (V
out
= 19.75 V)
Setting range (DC)
15 A (V
out
= 14.75 V) -
235 A (V
out
= 26.0 V)
15 A (V
out
= 14.75 V) -
130 A (V
out
= 20.5 V)
Permissible load in GTAW - DC TIG
100% duty cycle*
110 A (V
out
= 14.4 V)
Breaker 15 A: 80 A (V
out
= 13.2 V)
60% duty cycle*
125 A (V
out
= 15.0 V)
Breaker 15 A: 100 A (V
out
= 14.0 V)
40% duty cycle*
-
Breaker 15 A: 110 A (V
out
= 14.4 V)
25% duty cycle*
205 A (V
out
= 18.2 V)
Setting range (DC)
5 A (V
out
= 10.2 V) -
205 A (V
out
= 18.2 V)
5 A (V
out
= 10.2 V) -
130 A (V
out
= 15.2 V)
Permissible load in GTAW - AC TIG
100% duty cycle*
110 A (V
out
= 14.4 V)
Breaker 15 A: 75 A (V
out
= 13.0 V)
60% duty cycle*
125 A (V
out
= 15.0 V)
Breaker 15 A: 95 A (V
out
= 13.8 V)
40% duty cycle*
-
Breaker 15 A: 105 A (V
out
= 14.2 V)
25% duty cycle*
205 A (V
out
= 18.2 V)
Setting range (AC)
5 A (V
out
= 10.2 V) -
205 A (V
out
= 18.2 V)
5 A (V
out
= 10.2 V) -
130 A (V
out
= 15.2 V)
Permissible load in SMAW - Stick
100% duty cycle*
100 A (V
out
= 24 V)
55 A (V
out
= 22.2 V)
60% duty cycle*
125 A (V
out
= 25 V)
70 A (V
out
= 22.8 V)
40% duty cycle*
-
75 A (V
out
= 23.0 V)
25% duty cycle*
170 A (V
out
= 26.8 V)
-
Setting range (DC)
16 A (V
out
= 20.6 V) -
180 A (V
out
= 27.2 V)
16 A (V
out
= 20.6 V) -
130 A (V
out
= 25.2 V)