ESAB CUTMASTER 80
INSTALLATION
Manual 0-5396
3-2
5. Pass the cable being used through the access
opening in the back panel of the power supply.
Refer to Section 2 for power cable specifications.
!
CAUTION
The primary power source and pow-
er cable must conform to local elec-
trical code and the recommended
circuit protection and wiring require-
ments (refer to table in Section 2).
6. Connect the wires as follows.
• Set Jumper wires on the contactor. See il
-
lustration.
• Green / Yellow wire to Ground.
• Remaining wires to L1, L2 and L3 input. It
does not matter what order these wires are
attached. See the previous illustrations.
7. With a little slack in the wires, tighten the through
- hole protector to secure the power cable.
8. Reinstall the Power Supply cover per instructions
found in section 5.
9. Connect the opposite end of individual wires to
a customer supplied plug or main disconnect.
10. Connect the input power cable (or close the main
disconnect switch) to supply power.
3.04 Gas Connections
Connecting Gas Supply to Unit
The connection is the same for compressed air or high
pressure cylinders. Refer to the following two subsec-
tions if an optional air line filter is to be installed.
1. Connect the air line to the inlet port. The illustra-
tion shows typical fittings as an example.
NOTE!
For a secure seal, apply thread
sealant to the fitting threads, accord
-
ing to manufacturer's instructions.
Do not use Teflon tape as a thread
sealer, as small particles of the tape
may break off and block the small air
passages in the torch.
Art # A-07943
Hose Clamp
Regulator/Filter
Assembly
Inlet Port
Gas Supply
Hose
1/4 NPT or ISO-R
to 1/4” (6mm) Fitting
Air Connection to Inlet Port
Installing Optional Single - Stage Air Filter
An optional filter kit is recommended for improved filter
-
ing with compressed air, to keep moisture and debris
out of the torch.
1. Attach the Single - Stage Filter Hose to the Inlet
Port.
2. Attach the Filter Assembly to the filter hose.
3. Connect the air line to the Filter. The illustration
shows typical fittings as an example.
NOTE!
For a secure seal, apply thread seal
-
ant to the fitting threads, according
to the maker's instructions. Do Not
use Teflon tape as a thread sealer,
as small particles of the tape may
break off and block the small air
passages in the torch. Connect as
follows:
Summary of Contents for Cutmaster 40 SL60 1Torch
Page 9: ...This Page Intentionally Blank ...
Page 56: ...ESAB CUTMASTER 80 Manual 0 5396 GENERAL INFORMATION This page intentionally blank ...
Page 64: ...ESAB CUTMASTER 80 INTRODUCTION Manual 0 5396 2T 4 This Page Intentionally Blank ...
Page 68: ...ESAB CUTMASTER 80 INSTALLATION Manual 0 5396 3 4 This Page Intentionally Blank ...
Page 70: ...ESAB CUTMASTER 80 INSTALLATION Manual 0 5396 3T 2 This Page Intentionally Blank ...
Page 74: ...ESAB CUTMASTER 80 OPERATION Manual 0 5396 4 4 This Page Intentionally Blank ...
Page 89: ...ESAB CUTMASTER 80 Manual 0 5396 OPERATION 4T 15 This Page Intentionally Blank ...
Page 92: ...ESAB CUTMASTER 80 OPERATION Manual 0 5396 4T 18 This Page Intentionally Blank ...
Page 107: ...ESAB CUTMASTER 80 Manual 0 5396 PARTS LIST 6 5 A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13 ...
Page 115: ...ESAB CUTMASTER 80 Manual 0 5396 APPENDIX A 5 This Page Intentionally Blank ...
Page 119: ...This Page Intentionally Blank ...