![ESAB COOL 2 Instruction Manual Download Page 7](http://html1.mh-extra.com/html/esab/cool-2/cool-2_instruction-manual_2424738007.webp)
3 TECHNICAL DATA
0463 348 001
- 7 -
© ESAB AB 2017
3
TECHNICAL DATA
COOL 2
Power consumption
40 V AC / 2A, 50/60 Hz
Cooling power
1 kW
Noise
(Constant sound pressure when idling)
< 70 dB(A)
Coolant
"ESAB's ready mixed coolant, see the
"ACCESSORIES" chapter.
Coolant quantity
4.5 l
Maximum water flow
1.8 l/min
Max pressure lift for torch Q
max
4.6 bar
Operating temperature
-10° to +40°C
Transportation temperature
-20° to +55°C
Dimensions
(l × w × h)
680 × 330 × 230 mm
Weight
empty
15 kg
Enclosure class
IP23
The cooling unit is rated 500 A at 60% duty cycle at 77°F (25°C) ambient temperature.
Enclosure class
The
IP
code indicates the enclosure class, i.e. the degree of protection against penetration
by solid objects or water.
Equipment marked
IP23
is intended for indoor and outdoor use.