ESAB COOL 2 Instruction Manual Download Page 5

1 SAFETY

0463 348 001

- 5 -

© ESAB AB 2017

4.

Personal safety equipment:

○ Always wear recommended personal safety equipment, such as safety glasses,

flame-proof clothing, safety gloves

○ Do not wear loose-fitting items, such as scarves, bracelets, rings, etc., which

could become trapped or cause burns

5.

General precautions:

○ Make sure the return cable is connected securely
○ Work on high voltage equipment

may only be carried out by a qualified

electrician

○ Appropriate fire extinguishing equipment must be clearly marked and close at

hand

○ Lubrication and maintenance must

not

be carried out on the equipment during

operation

WARNING!

Arc welding and cutting can be injurious to yourself and others. Take precautions
when welding and cutting.

MALFUNCTION - Call for expert assistance in the event of malfunction.
PROTECT YOURSELF AND OTHERS!

CAUTION!

Class A equipment is not intended for use in residential
locations where the electrical power is provided by the
public low-voltage supply system. There may be potential
difficulties in ensuring electromagnetic compatibility of class
A equipment in those locations, due to conducted as well
as radiated disturbances.

NOTE!
Dispose of electronic equipment at the recycling
facility!

In observance of European Directive 2012/19/EC on Waste
Electrical and Electronic Equipment and its implementation
in accordance with national law, electrical and/or electronic
equipment that has reached the end of its life must be
disposed of at a recycling facility.

As the person responsible for the equipment, it is your
responsibility to obtain information on approved collection
stations.

For further information contact the nearest ESAB dealer.

ESAB has an assortment of welding accessories and personal protection equipment
for purchase. For ordering information contact your local ESAB dealer or visit us on
our website.

Summary of Contents for COOL 2

Page 1: ...Instruction manual 0463 348 001 GB 20170302 Valid for serial no 324 xxx xxxx COOL 2...

Page 2: ......

Page 3: ...welding equipment 8 5 OPERATION 9 5 1 Connections and control devices 9 5 2 Usage of the cooling unit 9 5 3 Coolant connection 9 5 4 Coolant pressure controller 9 6 MAINTENANCE 10 6 1 Inspection and...

Page 4: ...y precautions must meet the requirements that apply to this type of equipment The following recommendations should be observed in addition to the standard regulations that apply to the workplace All w...

Page 5: ...RS CAUTION Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low voltage supply system There may be potential difficulties in ensu...

Page 6: ...ooling unit COOL 2 is intended for cooling water cooled MIG MAG welding torches Accessories for the product can be found in the ACCESSORIES chapter of this manual 2 1 Equipment The cooling unit is sup...

Page 7: ...flow 1 8 l min Max pressure lift for torch Qmax 4 6 bar Operating temperature 10 to 40 C Transportation temperature 20 to 55 C Dimensions l w h 680 330 230 mm Weight empty 15 kg Enclosure class IP23...

Page 8: ...cause radio interference It is the user s responsibility to take adequate precautions 4 1 Location Position the cooling unit such that it s cooling air inlets and outlets are not obstructed 4 2 Power...

Page 9: ...t Turn OFF the cooling unit when welding MMA or using air cooled MIG TIG welding torches to avoid excessive wear of the pump Otherwise the pump will work against a closed valve Turn ON the cooling uni...

Page 10: ...ronments This results in reduced cooling capacity For this reason blow clean using compressed air at regular intervals The coolant system The recommended coolant must be used in the system otherwise c...

Page 11: ...recommended checks and inspections before sending for an authorized service technician Type of fault Corrective action Poor cooling effect Clean the cooling element using compressed air Check the cool...

Page 12: ...an standards CAN CSA E60974 1 and US standards ANSI IEC 60974 1 On completion of service or repair work it is the responsibility of the person s performing the work to ensure that the product still co...

Page 13: ...ASSEMBLY INSTRUCTIONS 0463 348 001 13 ESAB AB 2017 ASSEMBLY INSTRUCTIONS...

Page 14: ...ASSEMBLY INSTRUCTIONS 0463 348 001 14 ESAB AB 2017...

Page 15: ...DIAGRAM 0463 348 001 15 ESAB AB 2017 DIAGRAM...

Page 16: ...PUMP DATA 0463 348 001 16 ESAB AB 2017 PUMP DATA...

Page 17: ...463 348 001 17 ESAB AB 2017 ORDERING NUMBERS Ordering Number Denomination Type 0465 427 880 Cooling unit COOL 2 0459 839 092 Spare parts list COOL 2 Technical documentation is available on the Interne...

Page 18: ...B AB 2017 ACCESSORIES 0465 720 002 ESAB ready mixed coolant 10 l 2 64 gal Use of any other cooling liquid than the prescribed one might damage the equipment In case of such damage all warranty underta...

Page 19: ...ACCESSORIES 0463 348 001 19 ESAB AB 2017...

Page 20: ...Henares MADRID Tel 34 91 878 3600 Fax 34 91 802 3461 SWEDEN ESAB Sverige AB Gothenburg Tel 46 31 50 95 00 Fax 46 31 50 92 22 ESAB International AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWI...

Reviews: