![ESAB CIGWELD WeldSkill 205AC/DC Operating Manual Download Page 26](http://html1.mh-extra.com/html/esab/cigweld-weldskill-205ac-dc/cigweld-weldskill-205ac-dc_operating-manual_2424967026.webp)
INSTALLATION 3-4 0-5555
3.11 Foot Control, Part No. W4015800 (Optional Accessory)
Art # A-11338
Figure 3-1: Foot Control
Art # A-11339
1
2
3
4
5
6
7
8
Art # A-11340
Figure 3-2: 8 Pin Control Plug
Pin
Description
1
Not Used
2
Trigger Switch
3
Trigger Switch
4
Not Used
5
Potentiometer Maximum
6
Potentiometer Minimum
7
Potentiometer Wiper
8
Not Used
Table 3-1
Description
The CIGWELD Foot Control is a foot operated switch and potentiometer which starts and stops the welding
process and controls welding current through operation of the foot pedal. Refer to list below for compatible
Cigweld power sources.
Installation
Attach the 8-pin connector on the end of the cable to the 8-pin receptacle on the front of the welding machine.
To complete the connection, align the keyway, insert the plug, and rotate the threaded collar fully clockwise.