GB
5
5..2
2 O
Ov
ve
errllo
oa
ad
d
p
prro
otte
ec
cttiio
on
n
Caddy TIG HF is provided with a thermal cut-out to prevent overheating of the welding
power source. In the event of overload the supply voltage is interrupted, the yellow led on
the front goes on and an error code starts blinking on the display accordingly to the follow:
E01 = overtemperature
E03 = overload with respect to allowed duty cycle
In case of error E01 or E03 resetting takes place automatically as soon as the welding
power source has cooled down.
Error code E20 could also be displayed; in that case switch off and on again the machi-
ne: if E20 is still displayed, call Service.
5
5..3
3 M
Ma
aiin
ns
s
v
vo
olltta
ag
ge
e
c
co
om
mp
pe
en
ns
sa
attiio
on
n
Caddy TIG HF both has mains voltage compensation, which means that + 15% fluc-
tuation in the supply voltage produces a negligible variation in the welding voltage.
5
5..4
4
F
Fa
an
n
o
op
pe
erra
attiio
on
n
In order to reduce noise, no load consumption and metallic powder movement, Caddy
TIG HF has a special device that control the fan velocity; the higher is the internal tem-
perature the faster is the fun speed.
5
5..5
5
C
Co
on
nttrro
olls
s
a
an
nd
d
c
co
on
nn
ne
ec
cttiio
on
ns
s
1. Control
panel
2. Knob for adjusting the welding parameters
3. Green indicating led (correct mains connection)
4. Yellow indicating led (overheating)
5. Selection switch: MMA mode (light on led); TIG LIFT START mode (light on
led); TIG HF START mode (light on led)
6. Welding parameters and set up switch
7. Green led (welding current is selected)
8. Green led (ramp down time is selected)
9. Display
10. Terminal, minus pole, for connecting welding or return cable or TIG torch.
11. Terminal, plus pole, for connecting welding or return cable
12. Torch switch connector
13. Torch gas connector
14. Input gas connector for the gas hole from the argon cylinder
15. Mains switch
49