S0740 800 186/E080826/P50
-- 46 --
ct34i1
Recommended fuse sizes and minimum cable area
Tig 1500i
Tig 2200i/2200iw
TIG
MMA
TIG
MMA
Mains voltage
230 V
¦
10 %,
1
μ
50/60 Hz
230 V
¦
10 %,
1
μ
50/60 Hz
230 V
¦
10 %,
1
μ
50/60 Hz
230 V
¦
10 %,
1
μ
50/60 Hz
Mains cable area
mm
2
3G2.5
3G2.5
3G2.5
3G2.5
Phase current
I
1eff
9.1 A
11.5 A
11.5 A
13.4 A
Fuse
anti--surge
type C MCB
16 A
13 A
16 A
13 A
16 A
16 A
16 A
16 A
NOTE!
The mains cable areas and fuse sizes as shown above are in accordance with Swedish
regulations. Use the welding power source in accordance with the relevant national regulations.
OPERATION
General safety regulations for the handling of the equipment can be found in
the instruction manual. Read through before you start using the equipment!
Connections and control devices
1
Connection (+)
TIG: for return cable.
MMA:for welding cable or return cable.
7
Mains switch
2
Connection for the remote control unit
8
Mains cable
3
Control panel (see separate instruction
manual)
9
Connection for shiedling gas
4
Connection for the TIG--torch trigger switch
10
Connection BLUE, with ELP* for cooling
water from the cooling unit
5
Connection for gas to the TIG--torch
11
Connection RED for cooling water to the
cooling unit.
6
Connection (--) for TIG--torch
MMA: for return cable or welding cable
12
Refilling of cooling water
* ESAB Logic Pump, see ’Water connection’ below
Summary of Contents for Cadd Tig 1500i TA34
Page 8: ...S0740 800 186 E080826 P50 8 ct34_00 Tig 1500i with control panel TA34...
Page 9: ...S0740 800 186 E080826 P50 9 ct34_00...
Page 10: ...S0740 800 186 E080826 P50 10 ct34_00 Tig 2200i with control panels TA33 and TA34...
Page 11: ...S0740 800 186 E080826 P50 11 ct34_00...