General

This dual pulse Mig welding system has been designed and manufactured to specifications provided by

Bombardier, Inc..  The software is modified to provide eight separate schedules for each torch.  The first four

schedules (1-4) on each torch are dedicated to pulse welding of stainless steel in the synergic mode.  The

second four schedules (5-8) are dedicated to short or spray arc welding and have no synergic relationships.

This means that IIPM and VOLTS are entered separately depending if a short arc or spray arc weld condition

is required.  The following will detail the set-up and operation of this unique welding system.

Start Up

Assembly of the power source, feeder and interconnect cable is the same as specified in the general oper-

ating instruction manuals provided with the SVI-450i Power Source and Digipulse Dual wire feeder.  After

power up of the SVI-450i (575 Vac) and the  feeder, the windows on the feeder will display IPM=5 and

VOLTS=45 for a brief period.  This indicates that the stainless steel program (same as a standard Digipulse)

is running and the synergic curve is for .045-inch (1.2 mm) diameter wire.  These parameters CANNOT be

changed.  The windows will then display the last welding parameters set by the operator.  Place the “Remote/

Panel” switch on the SVI-450i power source in the “Remote” position and follow the instructions below.

Selecting System Presets

System parameters are those that affect 

BOTH

 torches and 

ALL

 schedules.  These parameters are always

active and should be set first.  They are:

Gas preflow preset

Gas postflow preset

Cold inch preset

Trigger selection (dual schedule operation)

Half speed run-in

Set the shield gas preflow parameters by holding down the “Purge” key and using the “Inc/Dec” key under

the IPM window to set a preflow time in 1/10 seconds.  Repeat the above for postflow using the key below the

VOLTS window.

The cold inching feature is a two speed design.  When placing the “Inch” key in the “up” position, the feed

motor will operate at 50 ipm for a period of 2-1/2 seconds.  This is for  “bumping” the wire to adjust the wire

stick-out from the contact tip.  After 2-1/2 seconds the wire feed speed will transfer to the cold inching speed

shown in the IPM window.  The wire feed speed can be further adjusted using the “Inc/Dec” key under the

IPM window.  This function is designed for wire threading.

The “Trigger Selection” option allows dual schedule operation.  This means that two welding schedules are

available to the operator on each torch.  This option is disabled when Rocker Switch #4 on Dip Switch #2 is

in the “closed” position.  Dip switch #2 is  located on the MPU board inside the feeder control box.  Place this

switch in the “open” position for “Trigger” selection (dual schedule operation).  Welding will always begin

using the current weld schedule selected.  “Double clicking” the torch trigger switch changes the welding

parameters to the next highest schedule number.  See diagram below.

Operating Instructions

Summary of Contents for BOMBARDIER SVI-450i

Page 1: ...F 15 565 February 1999 ...

Page 2: ...Wire Kit Bill of Material BM 31953 Control PCB D 31496 Power PCB D 674991 Section III 1 Digipulse Dual Control Assembly Dwg D 8 33387 Schematic Diagram D 33380 Wiring Diagram D 33381 Wire Kit Bill of Material BM 33397 Display PCB D 675236 J Gov PCB D 994236 I O PCB D 674994 MPU PCB C 18155 E Prom A 18090 2 Digipulse Dual Wire Feeder Assembly Dwg D 37843 with Bill of Material See Model No 33299 Sec...

Page 3: ... Presets System parameters are those that affect BOTH torches and ALL schedules These parameters are always active and should be set first They are Gas preflow preset Gas postflow preset Cold inch preset Trigger selection dual schedule operation Half speed run in Set the shield gas preflow parameters by holding down the Purge key and using the Inc Dec key under the IPM window to set a preflow time...

Page 4: ...s below Half speed run in is always on when using the pulse arc schedules 1 to 4 Half speed run in will also be on in the short spray arc schedules 5 to 8 when the arc voltage is 26 volts or higher Below 26 volts will result in full speed run in of the welding wire This option is enabled when Rocker Switch 1 on Dip Switch 2 is in the open position Dip switch 2 is located on the MPU board inside th...

Page 5: ...as and its ability to support both processes If spot welding is desired depress the torch trigger switch to be preset This action displays the current welding parameters for that torch Hold the Burnback Spot key in the up position and set a spot time in seconds in the IPM window Repeat this procedure for the other torch if desired Entering a spot weld time automatically disables the Trigger Select...

Page 6: ...d motor response by presetting the motor speed servo Release the pressure roll and pull the torch switch while depressing the Purge and Schedule Select key simultaneously Change the number 110 is standard in the IPM window using the Inc Dec key to a lower value if a faster motor acceleration is needed or a higher number for a slower motor acceleration Warning The motor response adjustment will be ...

Page 7: ...ted schematic layout Wiring Diagram D 34309 Rev E Removed reference to ICB P2 9 from ICB P3 2 and ICB P3 2 from ICB P2 9 Note The most current revision of the drawing is always on top Digipulse Dual Control Revision History Rev A Added label P N 954232 Schedule Select to front panel Rev B Removed the 6 pin P N 634772 and 8 pin P N 2062106 box receptacles and added a 19 pin P N 950762 box receptacl...

Page 8: ...F 15 565 2 99 ...

Reviews: