-- 7 --
bu20d1ea
5.1
Lifting instructions
Power source
Trolley and power source
Trolley2 and power source
5.2
Placing
Position the welding power source such that its cooling air inlets and outlets are not
obstructed.
5.3
Mains power supply
Check that the unit is connected to the correct mains power
supply voltage, and that it is protected by the correct fuse sizes.
A protective earth connection must be made, in accordance
with regulations.
Rating plate with supply connection data
Recommended fuse sizes and minimum cable areas
AristoMig U400
400 V 3
µ
50 Hz
Mains voltage
400 V
Mains cable area,
mm
2
4G4
Phase current, I
RMS
22 A
Fuse
Anti--surge
Type C MCB
25 A
32 A
NB:
The mains cable areas and fuse sizes as shown above are in accordance with Swedish regulations.
They may not be applicable in other countries: make sure that the cable area and fuse sizes comply
with the relevant national regulations.