INTRODUCTION

The

AristoMig U400

is a MIG/MAG / TIG welding power source, which can also be

used for MMA welding.
The power source is intended for use with the AristoFeed 30--4 or AristoFeed 48--4

wire feed units.
All the settings are made from the wire feed unit or control box AristoPendant U8.

ESAB’s accessories for the product can be found on page

17

.

3.1

Equipment

The AristoMig U400 power source is supplied complete with terminating resistor, 5m

return cable and instruction manual.

4

TECHNICAL DATA

AristoMig U400

Mains voltage

400V,

±

10%, 3

50 Hz

Primary current

I

max

MIG/MAG

I

max

MMA

I

max

TIG

36 A

38 A

29 A

No--load power

demand when in the energy--saving mode,

6.5 min. after welding

60 W

Voltage/current range

MIG/MAG

MIG/MAG, M2

MMA

TIG

8--60 V / 16--400 A

8-- 42 A

16-- 400 A

4 -- 400 A

Permissible load at

MIG/MAG

35% duty cycle

60 % duty cycle

100% duty cycle

400 A / 34 V

320 A / 30 V

250 A / 27 V

Permissible load at

MMA

35% duty cycle

60 % duty cycle

100% duty cycle

400 A / 36 V

320 A / 33 V

250 A / 30 V

Permissible load at

TIG

35% duty cycle

60 % duty cycle

100% duty cycle

400 A / 26 V

320 A / 23 V

250 A / 20 V

Power factor

at maximum current

0.65

Efficiency

at maximum current

85 %

Open--circuit voltage

MIG/MAG

MMA

TIG

55 -- 70 V

78 -- 90 V

78 -- 90 V

Operating temperature

--10 to +40

˚

C

Continual A--weighted sound pressure

<70 db

Dimensions, lxbxh

with cooling unit

625 x 394 x 496 mm

625 x 394 x 776 mm

GB

Summary of Contents for AristoMig U400

Page 1: ...GB Valid for serial no 322 xxx xxxx 334 xxx xxxx 347 xxx xxxx 445 xxx xxxx 524 xxx xxxx 0459 419 001 GB 060228 AristoMig U400 Instruction manual...

Page 2: ...wer supply 7 5 4 Terminating resistor 7 6 OPERATION 8 6 1 Connections and control devices 8 6 2 Turning on the power source 9 6 3 Fan control 9 6 4 Overheating protection 9 6 5 Cooling unit 9 6 6 Remo...

Page 3: ...uainted with the operation of the welding equipment Incorrect operation of the equipment may lead to hazardous situations which can result in injury to the operator and damage to the equipment 1 Anyon...

Page 4: ...ARD S Sparks spatter can cause fire Make sure therefore that there are no inflammable materials nearby NOISE Excessive noise can damage hearing S Protect your ears Use earmuffs or other hearing protec...

Page 5: ...max MMA Imax TIG 36 A 38 A 29 A No load power demand when in the energy saving mode 6 5 min after welding 60 W Voltage current range MIG MAG MIG MAG M2 MMA TIG 8 60 V 16 400 A 8 42 A 16 400 A 4 400 A...

Page 6: ...sure class The IP code indicates the enclosure class i e the degree of protection against penetration by solid objects or water Equipment marked IP23 is designed for indoor and outdoor use Application...

Page 7: ...fuse sizes A protective earth connection must be made in accordance with regulations Rating plate with supply connection data Recommended fuse sizes and minimum cable areas AristoMig U400 400 V 3 50...

Page 8: ...Power supply ON 2 Connection with ELP for cooling water to the TIG torch BLUE 11 Orange indicating lamp Overheating 3 Cooling water filler 12 Fuse 4 AT 4 Connection for welding current cable at MMA we...

Page 9: ...interrupting the welding current and lighting the orange indicating lamp on the front of the unit They reset automatically when the temperature has fallen 6 5 Cooling unit Water connection TIG welding...

Page 10: ...ed to the setting of current during MMA welding For more information about the operation of the remote control unit see the operating instructions for the control panel 7 MAINTENANCE Regular maintenan...

Page 11: ...te frequently S Check to see whether the air filters are clogged S Make sure that you are not exceeding the rated data for the power source i e that the unit is not being overloaded Poor welding perfo...

Page 12: ...Diagram 12 bu20e11a...

Page 13: ...13 bu20e11a...

Page 14: ...14 bu20e11a Cooling unit...

Page 15: ...ling unit 0458 625 884 Welding power source AristoMig U400 without cooling unit 0459 419 990 Spare part list AristoMig U400 The spare parts list is available on the Internet at www esab com Under Prod...

Page 16: ...AristoMig U400 Edition 060228 Spare parts list 16 ba37s Item Ordering no Denomination 1 0458 398 001 Filter 2 0458 383 001 Front grill...

Page 17: ...ba37a11a Trolley for AristoMig 0458 530 880 Trolley 2 for AristoMig for feeder with counterbalance device and or 2 gas bottles 0458 603 880 Guide pin 0458 731 880 Autotransformer TUA2 0459 145 880 Han...

Page 18: ...MIG MAG wire feed speed and voltage MMA current and arc force TIG current pulse and background current 0459 491 880 Remote control unit M1 10Prog CAN Choice of on of 10 programs MIG MAG voltage deviat...

Page 19: ...15 m 25 m 35 m Connection set water 1 7 m 5 m 10 m 15 m 25 m 35 m 0456 528 880 0456 528 890 0456 528 881 0456 528 882 0456 528 883 0456 528 884 0456 528 885 0456 528 895 0456 528 886 0456 528 887 045...

Page 20: ...50 92 22 ESAB international AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Air...

Reviews: