![ESAB Aristo Origo Feed 3004 Instruction Manual Download Page 16](http://html1.mh-extra.com/html/esab/aristo-origo-feed-3004/aristo-origo-feed-3004_instruction-manual_2424915016.webp)
5 OPERATION
0444 408 331
- 16 -
© ESAB AB 2020
4
Connection RED, for coolant from
welding torch
9
Connection for shielding gas
5
Connection for welding torch
10
Connection BLUE, for coolant from
cooling unit
NOTE!
Display (digital instrument) and coolant connections only available on certain models.
CAUTION!
Make sure the torch chosen is of the proper rating for the welding current to be used,
has the proper size and type of liner, the proper contact tip and the proper guide tube.
5.2
Water connection
The wire feed unit with water connection is equipped with a detection system
ELP
(
E
SAB
L
ogic
P
ump) which checks that the water hoses are connected. When connecting a
water-cooled welding torch, the water pump starts.
Detection only works with power sources that are equipped with ELP.
5.3
Wire feed pressure
Start by making sure that the wire moves smoothly through the wire guide. Then set the
pressure of the wire feeder's pressure rollers. It is important that the pressure is not too
great.
Fig 1
Fig 2