7 TROUBLESHOOTING
0459 419 401
- 17 -
© ESAB AB 2017
7
TROUBLESHOOTING
Try these recommended checks and inspections before sending for an authorised service
technician.
Type of fault
Action
No arc.
• Check that the mains power supply
switch is turned on.
• Check that the welding current supply
and return cables are correctly
connected.
• Check that the correct current value is
set.
Welding current is interrupted during welding. • Check whether the thermal overload trips
have operated (indicated by the orange
lamp on the front panel).
• Check the main power supply fuses.
The thermal overload trips operate frequently. • Check to see whether the air filters are
clogged.
• Make sure that you are not exceeding the
rated data for the power source (i.e. that
the unit is not being overloaded).
Poor welding performance.
• Check that the welding current supply
and return cables are correctly
connected.
• Check that the correct current value is
set.
• Check that the correct electrodes are
being used.
• Check the main power supply fuses.