OFF
Ignitor Button
Control Knob
Figure 19 - Control Knob In The OFF
Position (Manual Controlled Models)
Figure 21 - Pilot
OpERATION
Continued
OF
LO
T
Figure 20 - Control Knob In The OFF
Position (Thermostat Models)
Control Knob
Ignitor Button
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise
to the
OFF position.
2. Turn off any electric power to the appli-
ance if service is to be performed.
3. Close equipment shutoff valve (see Figure
16, page 13).
MANUAL LIGHTING
PROCEDURE
1. Remove front panel (see page 9).
2. Follow steps 1 through 7 under
Lighting
Instructions
, page 14.
3. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
4. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow step 9,
under
Lighting Instructions
, page 14.
5. Replace front panel.
THERMOSTAT
OPERATION
The thermostatic control used on these
models differs from standard thermostats.
Standard thermostats simply turn on and off
the burner. The thermostat used on this heater
senses the room temperature. At times the
room may exceed the set temperature. If so,
the burner will shut off. The burner will cycle
back on when room temperature drops below
the set temperature. The control knob can be
set to any heating level between 1 and 5. All
plaques will turn off and on.
Note: The thermostat sensing bulb mea-
sures the temperature of air near the heater
cabinet. This may not always agree with
room temperature (depending on housing
construction, installation location, room size,
open air temperatures, etc.) Frequent use of
your heater will let you determine your own
comfort levels.
TO SELECT
HEATING LEvEL
WARNING: When running
heater, set control knob at LOW,
MEDIUM or HIGH locked posi
-
tions. Never set control knob
between locked positions. Poor
combustion and higher levels of
carbon monoxide may result.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
Thermocouple
Ignitor Electrode
Pilot Burner