![ESA Ex22DSR Manual Download Page 5](http://html.mh-extra.com/html/esa/ex22dsr/ex22dsr_manual_2424608005.webp)
5.1 ENTER DATA IN SET MODE
SETUP / DISPLAY
DESCRIPTION
Range
Code Default
00
LANGUAGE SEL.
SL
ENGLISH
Display language selection
SL
01
DIGITAL INPUTS
C0
DISABLE
ENABLE / DISABLE inputs from external contacts
C0
03
PULSE TIME
B2x
0.50 sec.
Pulse time from 0.05 to 5.00 sec.
0.01÷5.00 B2x
0.50 sec
04
INTERVAL TIME
B3x
005 sec.
Interval time between ev. from 1 to 999 sec.
001÷999
B3x
5 sec
05
POSTCL INT.
B3c
005 sec.
Interval time between ev. during post-cleaning from 1 to 999 sec.
001÷999
B3c
5 sec
06
POST CYCLES
D1x
002 cycles
Number additional cycles after fan stop
00÷99
D1x
5
07
ELECTROVAL.N.
B1b
016 ev.
Selection Number of electrovalves
B1a
08
EV TEST
B10b
001 OFF
TEST Manual activation of
every single ev. from keyboard
B10
09
HOURS COUNTER
D14a
00000 Hours
Operation hours-counter
0÷65535
D14a
17
INPUT 2 SEL.
C0b
IN = C6
Input selection from external contact 2: IN=C6a / IN=D6a. See 2.2
Standard Features.
C0b