TECHNICAL DATA
*Remark: If the indoor module is not installed a fuse of 12,5 A is sufficient.
-15
-10
-5
0
5
10
15
20
2
3
4
5
6
t ( C)
CO
P
Bonus Air 10 - Outdoor unit
Refrigerant quantity
2.15 Kg
Refrigerant
R410 A
Noise
52 dB A
Output power at air 2 C /water 35 C
9,2 kW
Height (Outdoor unit)
1210 mm
Input power at air 2 C /water 35 C
2,4 kW
Width (Outdoor unit)
835 mm
COP at air 2 C /water 35 C
3,82
Depth (Outdoor unit)
310 mm
COP at air 7 C /water 35 C
4,35
Weight (Outdoor unit)
105 kg
COP at air -5 C /water 35 C
3,15
Indoor module
Power supply
400V/3P/50Hz
Power supply
400V/3P/50Hz
Compressor type
Scroll
Height (Indoor unit)
1320 mm
Recommended water flow
0,25 - 0,4 l/s
Width (Indoor unit)
575 mm
Input power of fan
2x40 W
Depth (Indoor unit)
700 mm
Recommended fuse*
25 A
Weight (Indoor unit)
60 kg
Water proof grade
IPx4
Auxiliary electric heater
3kW/6kW/9 kW
Max water Temperature
70 C
Water tank capacity
200 L
- 23 -
COP at different ambient temperatures for an outlet water
temperature of 35 C
Summary of Contents for BA-H050
Page 5: ...TRANSPORT AND STORAGE INSTALLATION AND SITING ES NORD 3 ...
Page 7: ...circulaton Water tank circulation pump ion ion 5 ...
Page 11: ...9 ...
Page 12: ...10 ...
Page 13: ...11 ...
Page 14: ...12 ...