background image

 

Trouble shooting   

 

Symptom 

Problems 

Solution 

Fluttering or 
spitting 

 

 

 

1.  Material level tool low. 

2.  Container tipped too far. 

3.  Loose fluid inlet connection. 

4.  Loose or damaged fluid tip/seat. 

5.  Dry or loose fluid needle packing 

nut. 

6.  Air vent clogged 

1.  Add material into container. 

2.  Hold more upright. 

3.  Tighten. 

4.  Adjust or replace. 

5.  Lubricate and or tighten. 

6.  Clear vent hole. 

Pattern is arc.

 

 

 

1.  Worn or loose Fluid nozzle. 

2.  Material build up on Air cap. 

1.  Tighten or replace Fluid nozzle. 

2.  Remove obstructions from holes, 

but don’t use metal objects to clean 

it. 

Pattern is not                 
Evenly spread.

     

 

 

 

1.  Material build up on Air cap. 

2.  Fluid nozzle dirty or worn. 

1.  Clean or replace Air cap. 

2.  Clean or replace Fluid nozzle. 

The center of Pattern 
too narrow. 

 

 

1.  Material too thin or not enough. 

2.  Atomization  air  pressure  too 

high. 

1.  Regulate material viscosity. 

2.  Reduce air pressure. 

Pattern  width  of 

fan-sharp  is  not 
enough. 

 

1.  Material too thick. 

2.  Atomization air pressure too low. 

1.  Regulate material viscosity. 

2.  Increase air pressure. 

 

Air  leaking  from 
air  cap  without 
pulling trigger   

 

 

1.  Sticking air valve stem 

2.  Contaminate on air valve or seat 

3.  Worn or damaged air valve or 

seat 

4.  Broken air valve spring 

5.  Bent valve stem 

1.  Lubricate 

2.  Clean 

3.  Replace 

4.  Replace 

5.  Replace 

Fluid  leaking  from 
packing nut 

 

1.  Packing nut loose 

2.  Packing worn or dry 

1.  Tighten, but do not restrict needle 

2.  Replace or lubricate (non-silicone 

oil) 

 

Excessive 
overspray 

 

1.  Too high atomization pressure 

2.  Too far from work surface 

3.  Improper stroking (arcing, gun 

motion too fast) 

1.  Reduce pressure 

2.  Adjust to proper distance 

3.  Move at moderate pace, parallel 

to surface. 

Will not spray 

 

1.  No pressure at gun 

2.  Fluid control not open enough 

3.  Fluid too heavy 

 

1.  Check air lines 

2.  Open fluid control 

3.  Thin fluid or change to pressure 

feed system. 

 

 

 

Summary of Contents for G7701L3.0

Page 1: ...odel No G7701L3 0 INDUSTRIAL SPRAY GUN CONTAIN Description Specification and Technical Data Important Safety Instruction Instructions for Operation Maintenance Storing Troubleshooting Repairs Parts List ...

Page 2: ...ety of pattern It is supplied with a 600 cc suction feed Alum Cup Specifications And Technical Data 1 Name of Parts 2 Technical Data Item No G7701L3 0 Air Inlet 1 4 Type of Feed Suction Standard Dia of Nozzle 2 0mm Optional Dia of Nozzle 1 8 2 0 2 5mm Recommended air pressure 3 0 4 0bar 44 58psi Max pressure of air 8 3 bar 120psi Paint Capacity 1000cc Avg Air Consumption 4 2 7 1cfm Pattern Width 1...

Page 3: ...rely tightened in case of leaking 9 Before painting make inspection for free movement of trigger and nozzle to insure tool can operate well 10 Never modify this tool for any other applications Only use parts nozzles and accessories recommended and accessories recommended by manufactures Instructions For Operation Preparation 1 After unpacking the product inspect carefully for any damage that may h...

Page 4: ...pendicular with spraying area then move it parallel for several times Stopping gun movement in mid stroke will cause a build up of paint and result in runs Do not fan the gun from side to side while painting This will cause a build up of paint in the center of the stroke and an insufficient coating at each end 3 Trigger the gun properly Start the gun moving at the beginning of the stroke BEFORE SQ...

Page 5: ...other components using a brush soaked in solvent 4 Reassemble the spray gun and spray a small quantity of solvent to eliminate all the residues in the paint passages ARNING NEVER USE METAL OR OTHER OBJECTS THAT COULD DAMAGE THE HOLES IN THE NOZZLE AND CAP NEVER IMMERSE THE SPRAY GUN COMPLETELY IN SOLVENT NEVER USE COMPONENTS OR PARTS THAT ARE NOT MANUFACTURER ORIGINALS Storing When not using spray...

Page 6: ...e too high 1 Regulate material viscosity 2 Reduce air pressure Pattern width of fan sharp is not enough 1 Material too thick 2 Atomization air pressure too low 1 Regulate material viscosity 2 Increase air pressure Air leaking from air cap without pulling trigger 1 Sticking air valve stem 2 Contaminate on air valve or seat 3 Worn or damaged air valve or seat 4 Broken air valve spring 5 Bent valve s...

Page 7: ...t Valve 24 Trigger Level 42 Pin Set 7 Air Inlet Plug 25 Nozzle 43 Pin 8 Gun Body 26 Rounded Nut 44 Switch Screw Seat 9 Washer 27 Steel Ball 45 Sealing Washer 10 Needle Housing Fluid 28 Nut 46 Switch Seat 11 O ring 8 7 1 85 29 Washer 47 Air Valve 12 Needle 30 Atomization 48 Switch Spring 13 Spring Core 31 Paint Inlet Plug 49 Washer 14 Needle Spring 32 Butterfly Nut 50 Sealing Washer 15 Fluid Adj Sc...

Reviews: