background image

 

1Touch

® 

switch - Quick Manual 

 
 
 

1Touch

®

 switch Quick Manual P/N 121693 

REV A 

5-19-2011 

 
 
 

 

WIRING 

 

The 1Touch has one 6-pin Deutsch connector. 

Mating connector:  

Deutsch DT06-6S  

Mating sockets:   

Deutsch 0462-201-16141  

Gold mating sockets:   

Deutsch 0462-201-1631 (* for CAN connections) 

Recommended wire gage:  

16-20 AWG   

Wedge lock:  

 

W6S           

 

PIN 

CIRCUIT 

DESCRIPTION 

SYS POWER 

(INPUT)  

– battery voltage (+9VDC…+32VDC)  

SYS GROUND 

(INPUT)  

– battery ground  

3 DIM 

INPUT 

(INPUT)  

– Configurable, analog or digital  

 

 

    (ground to battery voltage) 

CAN HIGH 

(DATA)  

– SAE J1939 CAN 2.0B, 250Kbits/s * 

CAN LOW 

(DATA)  

– SAE J1939 CAN 2.0B, 250Kbits/s * 

CAN SHIELD 

(DATA)  

– SAE J1939 CAN 2.0B, 250Kbits/s * 

 
 

SWITCH CAP INSTALLATION 

 

The 1Touch switch caps and labels are easily installed with no 
special tools required. 

The switch labels must be custom created.  Consult the full manual 
for detailed information about the label. 

1.  Adhere the switch label 

to the rubber switch pad.  
Take special care to 
place the label with 
proper orientation. 

 

2.  Place one corner of the 

switch cap into the corner 
of the switch opening. 

 

 

3.  Press the switch cap’s other 

corner firmly into place using 
finger pressure. 

 

 

 

 

 

ENABLING PASSWORDS 

 

If more than 

60

 seconds has elapsed since the 1Touch switch was 

powered you must enter the 

ENABLE

 password: 

1101 1011.

 

The panel’s switch backlighting will blink once to indicate the 
password has been accepted.  Standard password entry is now 
enabled for the next 

60

 seconds.   

 

 

 

ADDRESSING 

 

The 1Touch switch’s address may be set by entering the following 
password:  

1001 0010. 

Switches 0 and 1 are now lit and all other switches are OFF.  The 
red LED bar graph indicates the current address (see graphic 
below).   

Press switch 1 to 

decrease

 the address value.  Press switch 0 to 

increase

 the address value.   

Press any other switch to save the address and resume normal 
operation. 

 

LOADING DEFAULTS

 

To load the 1Touch’s defaults, enter the password: 

1001 1001. 

This sets all of the switch types to bi-stable, address to 0, device 
type set to 5, initial power states to OFF, LED indicator controlled 
internally, and network mode set to ES-Key. 

 