![Erreka VIVO-D102 Quick Installation And Programming Manual Download Page 2](http://html1.mh-extra.com/html/erreka/vivo-d102/vivo-d102_quick-installation-and-programming-manual_2424285002.webp)
10
D102: 230Vac/ 50Hz
D102M: 125Vac/ 60Hz
MO
TO
R
ENCODER
ST
O
P
M
MOTOR
ENCODER
P14
P15
P13
G1
G2
M
GND
SNG1
V+
CHG
BAT: (2x12V/1,2 Ah)
BATTERY
IN/OUT
ADO01
General connections
STOP CABLE CONNECTOR
:
connect to the release switch
(in the models with encoder
and release). In the models
without release, make an
electrical bridge.
G1
Blue (motor)
G2
Red (motor)
P14 (GND)
Mesh (encoder mesh) (
–
)
P15 (SNG1)
Green (encoder signal) (
S
)
P13 (V+)
Brown (encoder power supply) (+)
M114C
D1 and D2:
CL
(static)
Door closed
CL
(flashing)
Door closing
OP
(static)
Door open
OP
(flashing)
Door opening
XX
(countdown)
Door on standby
StOP
Operator unlocked
PA
(static)
Pause (operation not complete)
rS
(static)
Door searching for close position
D3 and D4:
C5
Closing safety device activated
E1
Encoder motor shudown
F1
Thrust limit exceeded
bA
Battery working
Ftço
Photocells defective (pre-testing)
Display indications