G

E114A

ELECTRICAL CABLING:

Element

Nº threads x section

Maximum length

A: Main power supply

3x1.5mm

2

30m

B: Flashing light / Traffic light

2x0.5mm

2

 / 3x0.5mm

2

20m

C: Photocells (Tx / Rx)

2x0.5mm

2

 / 4x0.5mm

2

30m

D: Pushbutton/wall key

2x0.5mm

2

50m

E: Operator (motor + encoder)

Duct (2x1mm

+ interior screened duct 

2x0.5mm

2

)

8m (maximum 25m with 

cable 2x2.5mm

2

)

F: Operator release

2x0.5mm

2

25m

G: Antenna

Coaxial cable 50

k

 (RG-58/U)

5m

Elements of the complete installation