9
VIVO-D102(M)
Quick installation and programming guide
English
IMPORTANT
NOTE
This quick guide is a summary of the complete installation manual. The manual contains safety warnings
and other explanations which must be taken into account. The installation manual can be downloaded by
going to the "Downloads" section at the Erreka website:
http://www.erreka.com/Automatismos/descargaDocumentos.aspx
G
E114A
ELECTRICAL CABLING:
Element
Nº threads x section
Maximum length
A: Main power supply
3x1.5mm
2
30m
B: Flashing light / Traffic light
2x0.5mm
2
/ 3x0.5mm
2
20m
C: Photocells (Tx / Rx)
2x0.5mm
2
/ 4x0.5mm
2
30m
D: Pushbutton/wall key
2x0.5mm
2
50m
E: Operator (motor + encoder)
Duct (2x1mm
2
+ interior screened duct
2x0.5mm
2
)
8m (maximum 25m with
cable 2x2.5mm
2
)
F: Operator release
2x0.5mm
2
25m
G: Antenna
Coaxial cable 50
k
(RG-58/U)
5m
Elements of the complete installation