10
N
L
ST1
ST2
SG.A
FCA
FCC
P289Z
General connections
Opening photocells (SG.A):
place DIP6 in
ON to enable testing.
Closing photocells (SG.C):
place DIP9 in ON
to enable testing.
Photocell testing
Encoder
For the correct operation of the
encoder, ensure DIP7 is in ON.
(photocells without testing)
(photocells with testing)
230V, máx. 60W
F1
Motor fuse (5x20):
230VAC: 2,5A
125VAC: 6,3A
F2
Electronic fuse
(5x20; 230VAC: 500mA)
F3
FT and AUX24V outputs fuse
(5x20; 315mA)
DL1
Barrier open
DL2
Radio code programming
indicator / Receiving radio
code
DL3
Radio code or operation
programming
DL4
Opening relay enabled
DL5
Closing relay enabled
DL6
Opening limit switch contacts
closed
DL7
Closing limit switch contacts
closed
DL8
Opening safety device
contacts closed
DL9
Closing safety device contacts
closed
DL10
Pedestrian key command
contacts closed
DL11
Total key command contacts
closed
DL12
Radio key command
DL13
Encoder signal
Operator working: DL13
comes on intermittently,
since the encoder sends the
signal in the form of pulses.
Operator shutdown: DL13
may be on or off, indistinctly,
depending on the position of
the encoder (high pulse or
low pulse).
DL14
Power supply
STOP pushbutton enabled (emergency stop)
: DL1 and DL3 flash simultaneously every 0.5 seconds.
Opening or closing photocell testing error:
DL1 and DL3 flash simultaneously every 2 seconds.
LED strip connections
The LED strip is an optional accessory which can be bought
separately.
It includes: a traffic light card (SMF), a power source
(PWR LED), an LED strip (LED) and the cables and glands
necessary.
There are two references:
•
AUL09: for 3m barriers
•
AUL05: for 4.5m barriers.
•
AUL06: for 6m barriers.
The "Transparent rubber" accessory MUST be installed in
order to install the LED strip.
This rubber is supplied separately, in lengths of 6m (AUL03),
4.5m (AUL04) and 3m (AUL08).
V+
COM
N
L
LED
(AUL05 / AUL06)
PWR LED
(AUL05/AUL06)
V
R
COM
P289Y