background image

G

E

F

A

B

D

C

TC

H

I

0

TEMIS

Quick Installation Guide

MSB-026/04

WARNING

Elements of the complete installation

150

160

170

180

190

150 160 170 180 190

A B

200

210

200 210

140

140

>120°

110°~120°

100°~110°

90°~100°

A

D

C

B

D Aprox

TA

TA

This quick guide is a summary of the complete installation manual. The manual contains safety warnings and
other explanations which must be taken into account. The installation manual can be downloaded by going
to the "Downloads" section of Erreka website:

http://www.erreka-automation.com

Electrical Wiring

A.B: 24v DC Motor(2x1mm²)
C: Photocell 2x0.5mm² (max 20m) 
D:  Control Box (3x1.5mm²) 
E:   Push Botton 2x0.5mm²(max 25m)

Assembly levels, inward opening

TEMIS It is not applicable to an insecure or lacking rigidity door nor solves the defects due to incorrect installation or mainte-

Check the following points before starting the installation:
1). Hinges are properly positioned and greased.
2). No obstacles in the moving area and no frictions between two gate leafs or with the ground while moving.
3). “C” value is 139mm.
4). “D” can be measured from the gate easily.
5). “A” = “C” + “D”
6). The value of “B” can be calculated from the value of “A” and the leaves opening angle.
Ex. If “A”=160mm with the leaves opening angle of 100 degrees, then the value of “B” is approximate 190mm.

Please make sure B and A are similar or the same in value that the leaves can be 
operated smoothly, also to reduce the burden of the motor.

Open Interior

F:  Key Selector(2x0.5 mm²)
G: Flash Light (2x0.5mm²)  
H.I: Electric Lock (2x1mm²)

TA: Open Stopper
TC: Closed Stopper

1

Summary of Contents for TEMIS

Page 1: ...ening TEMIS It is not applicable to an insecure or lacking rigidity door nor solves the defects due to incorrect installation or mainte Check the following points before starting the installation 1 Hi...

Page 2: ...completely horizontally Place the motor on rear bracket with screw A and nut B 1 1 1 Insert the key to the release slot 2 Turn counterclockwise to release the motor 1 Insert the key and turn clockwise...

Page 3: ...on extention Opening Time Duty Cycle Protection Grade IP Operation temperature Absorbed current A Absorbed Power W Manual Release Enclosure Dimensions 2 2M 200kg 110V 230VAC 50 60Hz SMART D201M SMART...

Page 4: ...3 K2 K1 J4 J3 J7 F1 DB1 J8 NC NO CO NC NO CO CO NO NC CO NO NC NC NO CO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 LED3 LED4 LED2 LED Display LED1 System Learning LED2 RF Lea...

Page 5: ...setting You would continue setting F2 2 please press SET to return the formal option The LED display shows the first two numbers as the first option F1 And then follow the operation and 2 3 until comp...

Page 6: ...6 0 ORVH 0 2SHQ 0 ORVH Advise If change the configuration of F2 you should program the system learning again The completion of system learning A For Double leaf gate D G installation Show RUN on LED...

Page 7: ...100 Full Speed 80 Full Speed Function ON Function OFF 70 Full Speed 50 Full Speed F6 3 35 Full Speed F6 4 25 Full Speed 2 sec 3 sec 4 sec 5 sec 6 sec 7 sec 8 sec 9 sec 10 sec OFF 3 sec 10 sec 20 sec...

Page 8: ...on key Pedestrian Mode Function key Auto Close Function key FC FD FE FF FG FH FI FC 0 FC 1 FD 0 FD 1 FE 0 FE 1 FF 0 FF 1 FG 1 FG 2 FG 3 FG 4 FH 0 FH 1 FH 2 FH 3 FH 4 FI 0 FI 1 FI 2 FI 3 FI 4 OFF ON OF...

Reviews: