![Erreka NET Quick Installation And Programming Manual Download Page 12](http://html1.mh-extra.com/html/erreka/net/net_quick-installation-and-programming-manual_2424293012.webp)
12
Complete programming chart
D1
D2
Parameter
D3
D4
Pre-
determined
option
Options or values
C
1
Motor turning direction
0
1
x
0
2
4
Disabled
5
Closing safety device (photocell or strip)
0
0
x
Device not installed
1
0
Device without testing
1
1
Device with testing
P
1
Total opening radio code programming
o
ç
2
Disabled
3
Barrier open/close programming
o
ç
F
1
Functioning mode
0
1
Automatic
0
2
x
Step-by-step
2
Standby in automatic mode
0...5. 0...9
15
59
= 59 sec.;
2.5
= 2 min. 50 sec., etc
3
Disabled
A
0
Flashing light
0
1
x
No warning
0
2
With warning
1
Garage light time
0...5. 0...9
03
59
= 59 sec.;
2.5
= 2 min. 50 sec., etc
2
Barrier speed
0
1...5
03
01
: minimum speed;
05
: maximum speed
3
Slow down speed
0
1...5
02
01
: minimum speed;
05
: maximum speed
4
Slowdown distance
0
0...5
00
00
: minimum distance;
05
: maximum distance
5
Disabled
6
Maximum thrust
0...1
0...9
05
01
: minimum thrust;
10
: maximum thrust
7
Closing
photocell
used during standby
(in automatic mode only)
0
1
Immediate close
0
2
x
Restart standby time
0
3
Has no effect
8
Pushbutton
operation during standby
(in automatic mode only)
0
1
Immediate close
0
2
x
Restart standby time
0
3
Has no effect
9
Opening mode
0
1
x
Opening in accordance with the mode
selected in the main functions (
F
)
0
2
Collective opening
(the control board
does not obey the commands during
opening)
0
3
Step-by-step opening
(the barrier halts if
a key command is activated during
opening. The barrier closes if activated
again)
ç
1
Operations carried out
X
X
I n d i c a t e s t h e c y c l e s c o m p l e t e d ,
multiplying the indicated figure by an
amount, for example:
68
indicates 6,800 cycles completed
6.8
indicates 68,000 cycles completed