background image

12

       

P187Z

+24Vdc

CN22

GND

G4 G5

GND

V+

P13

SNG1

P14 P15

SNG2

P16

GND

V+

P17

SNG1

P18 P19

SNG2

P20

ENCODER1

ENCODER2

MOTOR2

MOTOR1

CN1

3

G6

Lamp

.

G9 G10

VIVO-D201:

VIVO-D201M:

B

ATTER

Y

IN/OUT

CHG

VIVO-D201:

FT

VIVO-D201M:

VIVO-D201:

230Vac, max 2.300W

VIVO-D201M:

125Vac, max 1.250W

F2

ST

1

FT

1

P1 P2 P3

ST

2

FT

2

P4 P5 P6

ST

O

P

P7 P8

W

ARNING LIGHT

P9 P10

24V

P11 P12

LOCK

G7 G8

C

our

te

sy

Light

N L

POWER

+

P21 P22 P23

F3

F1

LB/ LR

P24 P25

EDGE

-FT

(Test)

AUX

24 Vdc

SW1

V+

GND

SNG1

G1 G2

GND

G3

A1

Operator 1

A2

Operator 2

G1/G4

Red cable (motor)

G2/G5

Blue cable (motor)

V+

Brown cable (encoder supply)

GND

Mesh (encoder mass)

SNG1

Green cable (encoder signal 1)

SW1

Main switch

Select the number of operators using 

C0

 (

C001

: one operator, 

C002

: two operators).

Programme 

C7

 for operation with encoder (

C701

).

For the BUL operator, programme 

C301

.

Electrical connections VIVO-D201(M)

Turning direction check

: after connecting the power and activating any of the key devices, the

gate makes a reset (the display shows

rS

): the gate closes until it reaches the stopper, assigning this

stopper with the position "gate closed" If it opens instead of closes during reset, change the turning
direction (

C101

 or 

C102

 for A1 and 

C201

 or 

C202

 for A2).

Reviews: