Relay configuration ( Relay1 and Relay 2)

The operating mode of the two relays can be set in 
separate way.
Each relay can be configured as follows:

!

PULSE

 

-

 

Pulse operating mode

: the relay excites at 

the reception of a good transmitter signal and remains 
excited until the transmitter key is released.

!

STEP -

 

Bistable operating mode

 : the relays excites at 

the first pulse and releases at the next one 

!

TIMED 6 SECONDS -

 

Timed operating mode:

at the end of the received signal the relay remains 
excited for further 6 seconds.

!

SHORT RANGE -

 

“Pedestrial operating mode” :

in 

this case the receiver sensitivity is reduced of 40 dB 
causing a big reduction of the radiocontrol range 
( Final range of about max 10 mt.) 

Structure of the sub-menu

YES

YES

NO

NO

MENU

CONFIG RECEIVER ?

CONFIG RECEIVER 
RELAY:1 ?

RELAY:1
STEP ?

RELAY:1
PULSE ?

RELAY:1
TIMED 6 SECONDS

RELAY:1
SHORT RANGE

NO

NO

Select the RELAY 1 or RELAY 2 configuration using the 
LEFT Key of the MASTER transmitter and confirm with the 
RIGHT key : the display will give the message:
EXECUTED OK and the program will return to the main 
menu.

Facility Code set-up

The “Facility Code “ (FC) is a number, in the range : 
“000” to “256”, sent by the transmitter with its own Serial 
Number (S/N).
The receiver is programmed to accept only transmitters 
which have 2 types of Facility Codes. 
Any transmitter with facility code different from the 2 
programmed won’t be accepted.
Through the following procedure it is possible to set the 
couple of Facility Codes.

Select the option : FACILITY CODE : 1?  from the 
receiver configuration menu using the LEFT key of the 
MASTER transmitter..
Confirm the choice and you will be asked for the new 
Facility Code.
The message prompts with the current number 
memorized for the Facility Code 1

F  A  C  I  L  I  T   Y     C  O  D  E  :  1 

 

C  H  E  C  K     F  O  R   

 

      0  0  1 

 

You are asked to change or confirm the memory settings. 
In the case above, the receiver accepts only transmitters 
with Facility code = 001.
Config the Facility Code making use of the MASTER 
transmitter, or the KEYPAD or by using the key B of a 
transmitter with the desired Facility code.

At the end appears the message: 

EXECUTED OK

 and 

the program return to the main menu.

The procedure to set the Facility Code 2 is similar to the 
other.
On the display will appear “Facility Code 2”.

F  A  C  I  L  I  T   Y     C  O  D  E  :  2 

 

C  H  E  C  K     F  O  R   

 

      0  0  1 

 

NOTE

 : the Facility code Null ( “000”) has a special 

meaning.
In this case the Facility Code check is completely 
disabled.

Summary of Contents for SEL2641R433-16P

Page 1: ...ct This product is addressed to manage the access in automatic door control systems This appliance has been carefully manufactured and checked The manufacturer has designed this system to assure the b...

Page 2: ...CD trimmer adijust 3 Terminal boards 4 Relay1 5 Relay 2 6 4 pin strip connector 7 RJ11 phone connector 8 Buzzer 9 D type 9 pin male connector 10 Plugs 11 Screws 12 Aerial net 13 Receiver box 1 2 4 3 5...

Page 3: ...memorization Main menu structure Menu Delete Pag 9 Single user cancellation All users cancellation Complete initialization of the receiver Menu Modify user Pag 10 Enable Disable Modify relay or key p...

Page 4: ...gs 4 Technical specifications Receiver Carrier frequency 433 92 MHz Local oscillator freq 6 6128 MHz Power supply 12 24 Vac dc Modulation AM ASK Number of memorizable users 812 1631 Number of relays 2...

Page 5: ...vious menu Activation of the LEFT key Cyclical scroll upwards a digit Activation of the RIGHT key Gives confirmation to the present digit and shifts the cursor to the next digit of the number Number s...

Page 6: ...ons ERONE advice 2 A telephone wire 0 6 mm is sufficient for the input of the receiver and the relay cabling Receiver power supply connecting clip 3 0V connecting clip 4 12 24 Vac dc Connect the outpu...

Page 7: ...A S T O R E M A S T E R Where 00000 is the Serial Number of the Master transmitter used With an answer YES the display shows EXECUTED OK and the transmitter is memorized On the first line of the disp...

Page 8: ...6 1 0 R E L A Y K E Y A Modify the parameters RELAY and KEY according to your needs by using the MASTER transmitter The next step allows to choose a single or a block memorization U S E R S N 2 0 6 1...

Page 9: ...ee memory and stored TX number will be updated MENU DELETE USER MEM DELETE USER MEM USER DELETE USER MEM ALL USER DELETE USER MEM INIZIALIZE RX DELETE USER MEM ALL USER All users cancellation This opt...

Page 10: ...the transmitter is enabled the procedure ends and the program returns to the main menu With an answer YES the following message appears E N A B L E U S E R A R E Y O U S U R E Modify relay or key para...

Page 11: ...r a spare receiver Data recovery from a backup memory Memory Visualization on the LCD The first option allows to visualize the data memory on the LCD display The visualization is carried out line for...

Page 12: ...to complete the list by hand with more information as the user name and the installation address ERONE 433 800 PASSWORD 11111 FACILITY CODE 000 00_ USER ADDRESS to be filled by hand USER N S N STATUS...

Page 13: ...of the transmitter card as shown in fig 13 Confirm with the RIGHT key of the MASTER transmitter The software begins the check of the connection P R O G R A M T X U S E R S N 0 0 6 0 9 C O P Y M E M O...

Page 14: ...the following message appears on the LCD C O P Y M E M O R Y O N N O T C O N N E C T E D Insert the memory or connect the telephone cable and confirm with the RIGHT key of the TX MASTER A warning mes...

Page 15: ...0 0 0 0 Confirm with the RIGHT key of the MASTER transmitter The password settings can be as follows 1 The current password is Null 00000 password disabled In this case you are asked for the new passw...

Page 16: ...de FC is a number in the range 000 to 256 sent by the transmitter with its own Serial Number S N The receiver is programmed to accept only transmitters which have 2 types of Facility Codes Any transmi...

Page 17: ...If the message is persistent check the memory position on the receiver memorize again and then start transfer again Memory full Last memory position use a previous position or replace a position alre...

Page 18: ...device the connecting cable has to be as follows 1 Connection Receiver RCS 433BMR PC Serial Port D type 9 pin Male connector 2 Connection RCS 433BMR PC Serial Port D type 25 pin Male connector Receiv...

Page 19: ...ity of the receiver the following accessories are available A TX PROGRAMMING CABLE with PROBE Fig 15 B CONNECTION RECEIVER RECEIVE CABLE fig 16 C SERIAL CABLE to a serial printer Fig 17 D BACKUP MEMOR...

Page 20: ...9 Fax 39 0438 455 628 E mail info erone com Web www erone com GUARANTEE Warranty period 24 months from the production date placed inside In this period if the appliance has any malfuction due to defec...

Reviews: