background image

Pag. 12

Print user list

With the choice “COPY MEMORY ON A PRINTER”, it is 
possible to print the list of the users stored to a Serial 
Printer  ( see connector 9 at pag. 2)  

The transfer parameters are the following:

BAUD RATE:

2400 BAUD

N BIT:

8

PARITY:

NONE

STOP BIT:

1

HANDSHAKE:

NONE

The data memory are transferred through the RS232C to 
the device connected to the D-type 9-pin male connector 
It is possible to connect also a PC or a Terminal with 
VT100 emulation ( see connection diagrams at pag. 19).
After the selection confirmation, on the LCD will appear 
2 messages:

during the printing:

COPY 
IN PROGRESS.....

at the end:

COPY
EXECUTED OK

Then the program return to the initial message.
The printout allows to complete the list by hand with 
more information as the user name and the installation 
address. 

***   ERONE  433/800   *** 

PASSWORD : 11111

FACILITY CODE : 000,00_

USER ADDRESS

  

to be filled by hand

USER N.

S/N

STATUS

RELAY

KEYS

USER NAME

0001

20609

E

1 / 2

A/B

    

to be filled by 

hand

0002

20608

E

1 B

0801

11910

E

1 / 2

A/B

*** End of List ***

Print events

Each time a transmitter excites a relay, a string message is 
sent to the RS232 output.
The format of the string is the following:

[CR] 

U

AAAA - 

F

BB- 

S

CCCCC - 

R

D - 

K

[LF]

Legend:

[CR] = 

Carriage Return;

[LF] = 

Line Feed;

U, F, S, R, K, = 

Code Letters ;

AAAA = 

User Number ( 0000 - 0807 )

BB = 

Facility Code ( 000 - 255); 

CCCCC = 

Serial Number ( 00000 - 65535 ) ;

D = 

Relay activated  ( 1 or 2 or 1/2 );

E = 

Transmitter key activated ( A, B, C, D );

“- “ = 

Blank .

Example 
Transmitter received with S/N =05310, Facility code = 02, 
User number :  001;
Transmitter key activated = A , Relay activated = 1 

Signal output : 

[CR] 

U0001

 - 

F02

S05310

 - 

R1

 - 

KA

 [LF]

Printout example

Summary of Contents for SEL2641R433-16P

Page 1: ...ct This product is addressed to manage the access in automatic door control systems This appliance has been carefully manufactured and checked The manufacturer has designed this system to assure the b...

Page 2: ...CD trimmer adijust 3 Terminal boards 4 Relay1 5 Relay 2 6 4 pin strip connector 7 RJ11 phone connector 8 Buzzer 9 D type 9 pin male connector 10 Plugs 11 Screws 12 Aerial net 13 Receiver box 1 2 4 3 5...

Page 3: ...memorization Main menu structure Menu Delete Pag 9 Single user cancellation All users cancellation Complete initialization of the receiver Menu Modify user Pag 10 Enable Disable Modify relay or key p...

Page 4: ...gs 4 Technical specifications Receiver Carrier frequency 433 92 MHz Local oscillator freq 6 6128 MHz Power supply 12 24 Vac dc Modulation AM ASK Number of memorizable users 812 1631 Number of relays 2...

Page 5: ...vious menu Activation of the LEFT key Cyclical scroll upwards a digit Activation of the RIGHT key Gives confirmation to the present digit and shifts the cursor to the next digit of the number Number s...

Page 6: ...ons ERONE advice 2 A telephone wire 0 6 mm is sufficient for the input of the receiver and the relay cabling Receiver power supply connecting clip 3 0V connecting clip 4 12 24 Vac dc Connect the outpu...

Page 7: ...A S T O R E M A S T E R Where 00000 is the Serial Number of the Master transmitter used With an answer YES the display shows EXECUTED OK and the transmitter is memorized On the first line of the disp...

Page 8: ...6 1 0 R E L A Y K E Y A Modify the parameters RELAY and KEY according to your needs by using the MASTER transmitter The next step allows to choose a single or a block memorization U S E R S N 2 0 6 1...

Page 9: ...ee memory and stored TX number will be updated MENU DELETE USER MEM DELETE USER MEM USER DELETE USER MEM ALL USER DELETE USER MEM INIZIALIZE RX DELETE USER MEM ALL USER All users cancellation This opt...

Page 10: ...the transmitter is enabled the procedure ends and the program returns to the main menu With an answer YES the following message appears E N A B L E U S E R A R E Y O U S U R E Modify relay or key para...

Page 11: ...r a spare receiver Data recovery from a backup memory Memory Visualization on the LCD The first option allows to visualize the data memory on the LCD display The visualization is carried out line for...

Page 12: ...to complete the list by hand with more information as the user name and the installation address ERONE 433 800 PASSWORD 11111 FACILITY CODE 000 00_ USER ADDRESS to be filled by hand USER N S N STATUS...

Page 13: ...of the transmitter card as shown in fig 13 Confirm with the RIGHT key of the MASTER transmitter The software begins the check of the connection P R O G R A M T X U S E R S N 0 0 6 0 9 C O P Y M E M O...

Page 14: ...the following message appears on the LCD C O P Y M E M O R Y O N N O T C O N N E C T E D Insert the memory or connect the telephone cable and confirm with the RIGHT key of the TX MASTER A warning mes...

Page 15: ...0 0 0 0 Confirm with the RIGHT key of the MASTER transmitter The password settings can be as follows 1 The current password is Null 00000 password disabled In this case you are asked for the new passw...

Page 16: ...de FC is a number in the range 000 to 256 sent by the transmitter with its own Serial Number S N The receiver is programmed to accept only transmitters which have 2 types of Facility Codes Any transmi...

Page 17: ...If the message is persistent check the memory position on the receiver memorize again and then start transfer again Memory full Last memory position use a previous position or replace a position alre...

Page 18: ...device the connecting cable has to be as follows 1 Connection Receiver RCS 433BMR PC Serial Port D type 9 pin Male connector 2 Connection RCS 433BMR PC Serial Port D type 25 pin Male connector Receiv...

Page 19: ...ity of the receiver the following accessories are available A TX PROGRAMMING CABLE with PROBE Fig 15 B CONNECTION RECEIVER RECEIVE CABLE fig 16 C SERIAL CABLE to a serial printer Fig 17 D BACKUP MEMOR...

Page 20: ...9 Fax 39 0438 455 628 E mail info erone com Web www erone com GUARANTEE Warranty period 24 months from the production date placed inside In this period if the appliance has any malfuction due to defec...

Reviews: