background image

The guarantee period of all Erone products is 24 months, beginning from the 
manufacture date. During this period, if the product does not work correctly, due 
to a defective component, the product will be repaired or substituted at the 
discretion of the producer. The guarantee does not cover the plastic container 
integrity. After sale service is supplied at the producer's factory.

ERONE is a trademark by ELPRO INNOTEK S.r.l.

Via Piave, 23 - I-31020 S.Pietro di Feletto (TV) - ITALY

Tel. +39.0438.450879 - Fax. +39.0438.457126

E-Mail: info @erone.com

Web: www.erone.com

R A D I O C O M A N D I

8

IS

-R

SV

E

R

U

K

 R

ev

4

 d

el

 1

7

.1

0

.2

0

0

1

5.6 ANEMOMETER INTERVENTION SPEED SETTING

(A+B)4 [Bip], C4 [Bip - Bip - Bip] and following:
A1 [Bip] :

for 20 Km/h ( default value )

B1 [Bip, Bip] :

for 30 Km/h

C1 [Bip, Bip, Bip] : 

for 40 Km/h

D1 [Bip, Bip, Bip, Bip] : 

for 50 Km/h or more.

It is possible to set the speed of the wind at which the awning automatically closes. The default 
value is 20 Km/h. The operation can be done only with a transmitter already memorised.

Fig. 13

5.7 TEST ANEMOMETER 
It allows to verify the correctness of the connection with the anemometer without having to 
simulate the intervention of the wind.

(A+B)4 [Bip], D4 [Biiiip - Biiiip - Biiiip, Biiiip], D1 [Biiiip, Biiiip, Biiiip, Biiiip]

To this point, making to 
manually turn the shovels of the 
anemometer, some beeps of 
confirmation are emitted by the 
buzzer. The exit from the phase 
of test anemometer effects with 
a pressure of the keys A., B or D 

Fig. 14

Summary of Contents for SEL 2641 R433-RM

Page 1: ...e You are recommended to read carefully this manual before using the product D I I N S T A L L A Z I O N E M A N U A L I N S T A L L A T I O N S E L 2 6 4 1 R 4 3 3 R M ERONE RADIO PROGRAMMER FOR ROLL...

Page 2: ...g system avoiding 2 TECHNICAL SPECIFICATIONS RADIOCOMANDI Fig 1 Radio programmer Fig 2 Wall transmitter Receiver s type Etherodyne Operating frequency 433 92 MHz Modulation AM ASK Input load 50 Ohm ch...

Page 3: ...perate in a sequential mode and up to 33 radio commands that operate with separated commands It is also possible the combination of single and multiple modes General or group command 4 INSTALLATION 4...

Page 4: ...SABLE PROCEDURE Once completed the fixing of the mechanics rolling shutter or awning identify the connections of the motor that has to unroll the awning or the rolling shutter The net C of the motor w...

Page 5: ...e transmitter as well 5 2 TRANSMITTER MEMORISATION During the first installation it is necessary to power just one receiver at a time in order to avoid multiple memorisations of the same transmitter i...

Page 6: ...D1 IThe first transmitter is indispensable for the memorisation of further radio commands Memorisation of further transmitter Es N 2 on the same receiver Sequential mode 1 A B 4 Bip 1 A4 Biiiiiiiiiiii...

Page 7: ...out of 180 Sec The time out setting allows to stop the motor in case of failure of the limit switches This operation has to be done by using the transmitter according the following sequence 5 4 2 Usin...

Page 8: ...ERVENTION SPEED SETTING A B 4 Bip C4 Bip Bip Bip and following A1 Bip for 20 Km h default value B1 Bip Bip for 30 Km h C1 Bip Bip Bip for 40 Km h D1 Bip Bip Bip Bip for 50 Km h or more It is possible...