3B - Memory full

When the receiver memory is full and a memorization procedure is started,  both the leds LV and LR   blink 3 times.

3C - Full memory erase

This operation is possible both 

with the transmitter keys (1)

 and 

with the receiver push buttons (2).

1)

: Keep on pushed simultaneously the keys A and B of a TX whose codes are presents in  the memory of the RX; 

the buzzer emits a bip and the leds turns on for a while; within 2 sec. keep on pushed the key A of the same TX for 4 
sec.: the led LR is turned on and the buzzer sounds a long bip ( “biiiiiiip”).
Within 4 sec.( before the end of the long bip) push again simultaneously A and B for other 4 sec.; at this point will 
occur 3 blinks of LR and LV and 3 long bips of the buzzer ( biiiip - biiiip - biiiip”). 
At the end of this operation all the codes TX present in the memory are erased.

2)

:

 

Keep on pushed PR of the receiver until the red led LR is turned on.

 

Afterwards, keep

 

on pushed simultaneously 

PV

 and

 PR

 for 

4 sec

.  The receiver will give the operation 

confirmation with 3 blinks of the leds and 3 long bips of the buzzer ( “Biiiiip - Biiiiip - Biiiiip”).

4A - Relay configuration display

Keep on pushed 

PR (or PV)

 of the receiver for 4 sec. The configuration of the relay is displayed by the 

corresponding led  according the following table :

Relay operating mode ( RR or RV )  

        Led light type (LR or LV)

Pulse relay

Continuous light

Latching relay

Slow blinking

Timed relay

Fast blinking

4B - Relay programming

The receivers are factory set to Pulse mode.To change the mode follow these steps ( Fig. 4) :
1. Press desired relay button on receiver to be programmed ( PV or PR ) for 4 seconds. LED will illuminate 
displaying relay status. Use Table 5 to determine the status.
2. Within 1 second press PR to change the relay mode. 
The relay mode will change according to the diagram of Fig. 4

Red relay RR

Green relay RV

Not allowed configurations

latching

timed

timed

timed (with different delay times)

4C - Relay RR (RV) configuration 

-

 

Fig. 4

The operating mode of the relay is cyclic, with the possibility to change the mode according the following rules:

-If the relay is set as pulse:

it becomes latching and after timed;

-If the relay is set as latching:

it becomes pulse;

-If the relay is set as timed:

it becomes pulse.

4E - Relay  RR ( RV) timing settings 

- Fig. 5

The modification for the relay settings, with the timing, can be done only if the relay has been set as pulse.
Push the button 

PR

 

(PV)

 of the receiver for 4 sec.;the led LR (LV) will turn on and will display the operating mode set 

for the relay RR (RV). If the led blinks slow or fast push again PR for 1 second and the relay will be set as pulse. Then 
push PR for 1 second and the led LR (LV) switches off. Afterwards, within 2 seconds, begin to insert the selected relay 
time, by pushing on the buttons PR and PV according to Table 12 and considering that PR has weight of "0" while PV 
has weight "1". 

NOTE

The last pressures on PR of the sequence are not necessaries.

Example 1: 8 sec. delay : input the sequence : PR - PR - PR - PV - PR - PR - PR.
Example 2: 2 min delay.: Input the sequence : PV - PR - PR - PR - PR - PR - PV.
..................................................................................................................................................

GUARANTEE

The guarantee period of the product is 24 months, beginning from the manufacturer date. During this period, if the 
product does not work correctly, due to a defective component, the product will be repaired or substituted at the 
discretion of the producer. The guarantee does not cover the plastic container integrity. After-sale service is supplied 
at the producer's factory.

1C - Technical specifications

Receiver type:

Superheterodyne. 

Demodulation:

AM/ASK.

Operating frequency:

433,92 MHz.

Local oscillator frequency:

6,6128 MHz.

Intermediate frequency:

10,7 MHz.

Sensitivity (for good signal):

-115 dBm.

Input impedance:

50 Ohm.

Supply voltage :

 12 or 24 V ac/dc.

Current consumption:

at rest:

25 mA 

with relay excited:

55 mA

Number of relays:

2 (1NO, 1NO or NC).

Commutable max power:

24W or 24VA .

Max codes number:

85.

Operating temperature:

from -20  to + 70 °C.

Dimensions ( Fig. 1 ):

105 x 45 x 28 mm.

Weight:

65 gr.

1D - Main features

!

Memory for 85 transmitter keys;

!

Self-learning and erasing of the transmitter code simply using the transmitter keys, without accessing to the 
receiver board;

!

Display of the transmitter key number;

!

Display of the memory position for the last memorized transmitter;

!

Overwrite of a transmitter code;

!

Programmable operation of the relays: pulsing, latching and timed;

!

Programmable delay of release for the relays from 1 sec. to 10 hours;

!

Full memory cancellation.

1E - Receiver detail 

( Fig. 2)

LR:

Red led

LV:

Green led

PR:

Red push-button PV:

Green button

RR:

Red relay

RV:

Green relay

1F - Connections 

(Fig. 2)

Power-supply :

terminals 1 ,  2 : 12 Vac/dc

Antenna : terminal 9   : shield 

terminals 1 , 3 : 24 Vac/dc

terminal 10 :  core. ( RG 58)

Relay Outputs: terminals 4,5 : NO contact (red relay)

terminals 6,7: NO contact green relay)
terminals 6,8: NC contact green relay)

2A  - Transmitter memorizing

The code of each transmitter key can be memorized into the receiver in 2 different ways:
A - Directly on the receiver, by using the receiver push-buttons PR or PV.
B - Far from the receiver, by using the transmitter keys.

A) Direct memorization - 

To program a transmitter at the receiver.

1 - Select the relay to be programmed Green (PV) or Red (PR)
2 - Push desired relay key for 2 seconds or until LED comes on 
3 - Within 2 seconds press desired transmitter key to store in receiver memory.
LED light should blink and relay should cycle.

B) Remote programming mode : 

To program transmitters thru the use of a transmitter.

Note

: To utilize this mode the receiver must  first have at least one transmitter programmed into the receiver.

1 - Programming request - Push both keys of the transmitter that is already stored in the receiver until the receiver 
“beeps”;
2 - Programming entry - Release both keys and immediatlely press A or B key to select the corresponding relay to be 
programmed and hold key for 4 seconds;
The LED light of corresponding relay will turn on and “beep” will be continuous;
3 - Memorization - Within 2 seconds press new transmitter button to be memorized.

Example

Memorization of a second transmitter ( TX2) with key A on relay red RR and key B on relay green RV into 

a receiver with a transmitter (TX1) already stored:

Push keys A+B of TX1(bip); Push key A of TX1 for 4 sec.(Biiiiiiiip); push key A of TX2 within 2 
sec.
Push keys A+B of TX1(bip); Push key B of TX1 for 4 sec.(Bip, Bip, ...Bip); push key B of TX2 
within 2 sec.

NOTE

 : The memory capacity is of 85 transmitter keys. That means that a 4 keys transmitter needs 4 memory 

positions. It is possible to display the memory position by following the procedure 2B. 
A transmitter key can be memorized on each relay RR or RV but not on both.

2B  - Display of the transmitter memory position

By following the present procedure it is possible to display the position occupied by a given transmitter key.

1) Push the transmitter key for which it is necessary to know the memory position and verify the activation of the 
relay and the led.
2) Push the button 

PR

 of the receiver for 1 second.

At this point begins a sequence of 7 total blinks of the two led lights LR and LV: by taking a note of what color light 
blinks, it is possible to obtain the memory position, according to the  table 4:

Example

:

 Transmitter blinks the following seven ti

m

es after pushing the red relay (PR) key: 

RED  -  RED  -  GREEN  -  GREEN  -  RED  -   RED  -   RED 
This corresponds to the 12th position.

2C - Overwrite of an already stored Transmitter code 

1 - Determine transmitter key memory position ( see section 2B)
2 - Press corresponding relay programming key on transmitter for 4 seconds.
3 - Within 2 seconds press (

PV

)

4 - Within 2 seconds enter the transmitter memory position of existing transmitter by using ( 

PR red

 ) and ( 

PV green

) accordingly. There must be a total combination of seven button pushed ( PV or PR) to match the 

memory position of existing transmitter.
5 - Within 1 second press the new transmitter key to be programmed.

The previous transmitter key will be removed and replaced by the key pressed in step 5.

3A - Memory capacity display

This procedure allows to display the number of occupied memory positions.

1) Push the button 

PV

 of the receiver for 1 second.

At this point the receiver begins a sequence of 7 lightings of the leds LR and LV.
Referring to that it is possible to obtain the number of the occupied memory positions, according to tab.4.

 

DEUTSCH

1 - 

2 - Handsender

!

Erone 024A Mod.  S2TR 2641 E2/E4/E2M:

Handsender 2,4 Tasten, 2 Tasten Master;

!

Erone 433 Mod.  SETR 2641 AM2:

Mini Handsender 2 Tasten;

!

Erone 433 Mod.  SETR 2641 TM:

Wand Handsender 4 Tasten;

3 - Technische daten 

4 - Funktionen

5 - 

Allgemein

Der Empfänger SEL 2641 R433-IP (Abb. 1) ist eine Komponente unseres Funksystems 433, um Automationen und 
elektrische sowie elektronische Systeme fern zu steuern. Dank der hochsicheren Codierung, „Rolling Code“, 
können wir einen manipulationssicheren Betrieb gewährleisten. Der vom Handsender gesendete Code ändert 
sich bei jeder Aktivierung und der Mikrocontroller im Empfänger syncronisiert alle eingelesenen Sender im System. 
Die Programmierung erfolgt selbstlernend durch 2 Tasten

.

Die Empfänger  entspricht den eropäischen Normen 73/23/CEE, 89/336/CEE, EN 60065.

Empfängertyp: Superheterodyne
Modulation: AM/ASK
Frequenz: 433,92 

MHz

Frequenz des lokalen Oszillators: 

6,6128 MHz

Zwischenfrequenz: 10,7 

MHz

Empfindlichkeit(für erfolgreiches Signal): 

-115 dBm

Eingangsimpedanz: 50 

Ohm

Spannungsversorgung: 12/24 

VAC/DC

Ruhestrom: 25 

mA

Laststrom: 55 

mA

Relaisanzahl: 

2 ( 1 NO/ 1 NO-NC) 

Leistung

24 W

Betriebstemperatur  

- 20 °C bis + 70 °C

Abmessung ( Abb. 1): 

105 x 45 x 28 mm

!

Funkfernprogrammierung über Handsender (Einlernen und Löschen der Codes);

!

85 Codes speicherbar;

!

Anzeige der gespeicherten Codes;

!

Anzeige der Speicherposition des letzten empfangenen Codes;

!

Überschreiben von gespeicherten Codes;

!

Vollständige Löschung des Codespeichers am Empfänger oder über Handsender;

!

Programmierbare Relais : monostabil, bistabil und Zeitverzögert.

Zeichenerklärung 

LR: rote LED
PR: rote Taste
RR: rotes Relais
LV: grüne LED
PV: grüne Taste
RV: grünes Relais

6 - Anschlüsse 

( Abb. 2)

Einspeisung: 

Antenne: ( RG58 )

Klemme 1 und 2:   12 VAC/DC

Klemme 9:      Schirmung

Klemme 1 und 3:  24 VAC/DC

Klemme10:    Antenne

Relaisausgang:

 

Klemme 4 und 5 : Kontakt NO (rotes Relais)
Klemme 6 und 7 : Kontakt NO (grünes Relais)
Klemme 6 und 8 : Kontakt NC (grünes Relais)

   

Led blinks 

   Green LED

1

2

4

8

16

32

64

 

 

 

Red  LED

0

0

0

0

0

0

0

Tab. 4

Tab. 5

Tab. 6

Summary of Contents for EL2641 R433-IP

Page 1: ...abella 1 Led acceso 1 2 3 4 5 6 7 Peso colore verde 1 2 4 8 16 32 64 Peso colore rosso 0 0 0 0 0 0 0 Esempio Sequenza di accensione led LR LR LV LV LR LR LR Il numero ottenuto sarà 0 0 4 8 0 0 0 12 Perciò il trasmettitore si trova nella posizione 12 di memoria 2C Sovrascrittura codici TX già presenti in memoria 1 Premere PR o PV del ricevitore per 4 sec il relativo led si accende 2 Entro 2 sec pre...

Page 2: ...ect memorization To program a transmitter at the receiver 1 Select the relay to be programmed Green PV or Red PR 2 Push desired relay key for 2 seconds or until LED comes on 3 Within 2 seconds press desired transmitter key to store in receiver memory LED light should blink and relay should cycle B Remote programming mode To program transmitters thru the use of a transmitter Note To utilize this mo...

Page 3: ...mit verschieden zeiten 9 2 Relaisfunktionsänderung rotes Relais RR grünes Relais RV Abb 5 Die Taste PR PV des Empfängers für 4 Sek betätigen die rote LED LR grüne LED LV leuchtet auf und zeigt die eingestellte Funktion an wie in Punkt 9 0 beschrieben ESPAÑOL 1A 1B 1C 1D 1F Leyenda Receptor Fig 2 LR Led Rojo PR Pulsador Rojo RR Relè Rojo LV Led Verde RV Relè Verde PV Pulsador Verde 2A Memorizaci n ...

Page 4: ...os diferentes pero el tiempo que asumen ambos es el último introducido 2 en la configuración Biestable Temporizado es obligatorio que el relé verde RV esté en modo biestable y que el relé rojo RR esté en modo temporizado Cambio del funcionamiento del relé rojo RR relé verde RV Fig 4 Pulsar el botón PR PV del receptor durante 4 segundos el LED rojo LR LED verde LV se enciende e indica el modo de fu...

Reviews: