background image

PIR-018

PASSIVE INFRARED DETECTOR

2824-00005                                                                                                                                                               Page 8 of 10

Annex 2:

Two Way Communication RS 485

Introduction

The PIR-018 is equipped with a RS 485 interface for two-way communication between the detector and a PC or other control

device. This communication link is used for detector set-up and remote adjustments as well as for signal monitoring (see

also annex 3).

It can either be used temporarily for installation or permanently wired for remote access to the detector from the control room.

RS 485 can accommodate up to 32 detectors on the same data bus with a maximum bus length of 1’000 m – provided the

detectors have all different ID’s and the data link is properly terminated. If in doubt consult the manufacturer.

1

2

n

IF 485A

Temporary Connection for Installation and Configuration

For this, the use of the interface module PIR-IF485A is recommended (see section 12. above). The test socket carries V+,

GND and the two RS 485 ports A and B. The detector needs to be opened for access to the test socket and closed again after

the adjustments. All the adjustments and display functions as detailed in annex 3 are possible without further equipment.

Installation and Configuration for Permanent Wiring

For permanent connection of the RS 485 communication link to a control room the two RS 485 ports A and B are also

accessible on the terminal block. The connector board contains all components required for protection of the communication

link.

In this mode it is not only possible to do all adjustments and signal monitoring remotely from the control room but also

eventually to use the RS 485 link for alarm signalling.

When planning to use the PIR-018 in this configuration please consult the manufacturer for details about the protocol

definitions.

Summary of Contents for PIR-018

Page 1: ...nwanted alarms The universal bracket is equally suited for wall mounting using screws or pole mounting using steel bands through the slots It is very important that the cover of the PIR 018 is securel...

Page 2: ...field of view is terminated by a natural or artificial background at the end of the range Vertical alignment is optimal when the upper edge of the field of view is at 1 5 to 2 5 m above ground at the...

Page 3: ...ic coverage of the detectors Actual detection zones depend on the mounting height and exact alignment When walk testing the unit the threshold level will increase as a result of the signal generated b...

Page 4: ...reshold levels depending on its strength The time constants for increase and decrease are chosen in a way to adapt to gradual changes Signals generated by a person moving within the specified speed ra...

Page 5: ...RS 485 Data Bus If the DIP Switches 1 and 2 are both set to on the detection performance can be adjusted via the RS 485 two way communication port Overall sensitivity of the PIR 018 can be set to any...

Page 6: ...been designed to be virtually maintenance free but the following precautions are recommended 1 Visual inspection of the front window for accumulation of dirt on the outer surface or damage at interva...

Page 7: ...system using other physical means of detection e g VMD Any liability for direct or indirect damage resulting from the use of the PIR 018 as a detection device is explicitly disclaimed The information...

Page 8: ...Configuration For this the use of the interface module PIR IF485A is recommended see section 12 above The test socket carries V GND and the two RS 485 ports A and B The detector needs to be opened fo...

Page 9: ...ation moving in the wind and or other sources of disturbance it is possible that unwanted alarms occur Monitoring and interpreting the information supplied by the installation software will help findi...

Page 10: ...l be generated and saved as DDMMYYAB BMP where AB is used for identification of files within one day This function is not possible when the display is frozen n to reset the thresholds to the minimum v...