background image

PIR-018

PASSIVE INFRARED DETECTOR

2824-00005                                                                                                                                                                 Page 1 of 10

Introduction

The PIR-018 is a highly sensitive Passive Infrared Detector designed for detection outdoors with a wide angle, volumetric

differential field of view. It incorporates microprocessor controlled signal processing including signal shape analysis,

adaptive threshold level by feedback of environmental effects, temperature compensation and rejection of disturbance

signals.

Sensitivity adjustments are done with DIP-Switches for each individual unit in function of the required detection range in order

to adapt to the specific needs of an installation.

In addition to the hardware settings, adjustments can be made in a two way communication mode and signals displayed on

a PC screen by using the optional installation software and RS 485 com munication inte rface module.

Mounting and Installation

The mounting structure should be stiff enough and resist to significant deflections in windy conditions. Movement of the PIR-

018 caused by vibrations or other movements will result in swings of the field of view covered by the PIR-018 and could

cause disturbance signals. These unwanted signals may lead to an increase of the alarm threshold level which reduces the

detection probability or in certain cases can lead to unwanted alarms.

The universal bracket is equally suited for wall mounting (using screws) or pole mounting (using steel bands through the

slots).

 

It is very important that the cover of the PIR-018 is securely tightened. It must be tightened with the two screws to the

point where it cannot be closed further with reasonable force. There will then be hardly any gap between the cover and

the bottom part of the housing (considerably less than 1 mm).

The cable entry assembly should not be changed without authorisation by the manufacturer. It is specifically designed to

allow air entry and exit so that the inside of the PIR-018 is always at atmos pheric pressure. This prevents moisture being

sucked into the PIR-018 by drop of internal pressure likely to happen when rainfall rapidly cools down a unit warmed up in

the sun.

The nut on the cable entry assembly should be tightened to clamp the cable in place with the nylon grip. If the cable diameter

is too small to be held by the grip, insulation tape should be wound around the cable to increase the outside diameter to a

suitable size.

Connecting the PIR-018

For the definition of the connector board and terminal block see annex 1.

Alarm Signalling

There are three types of alarm signalling from the 

PIR-018

:

 

one SPST potential-free relay contact

 

an open collector transistor to negative supply rail

 

an RS 485 two way communication link (see annex 2 for details)

The relay contact opens and the transistor switches to low resistance on alarm.

Summary of Contents for PIR-018

Page 1: ...nwanted alarms The universal bracket is equally suited for wall mounting using screws or pole mounting using steel bands through the slots It is very important that the cover of the PIR 018 is securel...

Page 2: ...field of view is terminated by a natural or artificial background at the end of the range Vertical alignment is optimal when the upper edge of the field of view is at 1 5 to 2 5 m above ground at the...

Page 3: ...ic coverage of the detectors Actual detection zones depend on the mounting height and exact alignment When walk testing the unit the threshold level will increase as a result of the signal generated b...

Page 4: ...reshold levels depending on its strength The time constants for increase and decrease are chosen in a way to adapt to gradual changes Signals generated by a person moving within the specified speed ra...

Page 5: ...RS 485 Data Bus If the DIP Switches 1 and 2 are both set to on the detection performance can be adjusted via the RS 485 two way communication port Overall sensitivity of the PIR 018 can be set to any...

Page 6: ...been designed to be virtually maintenance free but the following precautions are recommended 1 Visual inspection of the front window for accumulation of dirt on the outer surface or damage at interva...

Page 7: ...system using other physical means of detection e g VMD Any liability for direct or indirect damage resulting from the use of the PIR 018 as a detection device is explicitly disclaimed The information...

Page 8: ...Configuration For this the use of the interface module PIR IF485A is recommended see section 12 above The test socket carries V GND and the two RS 485 ports A and B The detector needs to be opened fo...

Page 9: ...ation moving in the wind and or other sources of disturbance it is possible that unwanted alarms occur Monitoring and interpreting the information supplied by the installation software will help findi...

Page 10: ...l be generated and saved as DDMMYYAB BMP where AB is used for identification of files within one day This function is not possible when the display is frozen n to reset the thresholds to the minimum v...